Operation
ECA 100 ipro RC
The units are switched on/off either on the RLS RC room air control, with the DS RC radio switch, or with a window radio contact to be provided by the customer.
ECA 100 ipro RCH
The unit is barrier-free. Air extraction takes place according to the automatic humidity function. If there is little humidity, the unit switches off completely.
Program | Apartment size |
P1 | 30 m² / 50 m² / 70 m² |
P2 | 90 m² / 110 m² / 130² / 140 m² |
RLS RC program for ECA ...ipro RC/KRC/RCH/KRCH | System level 0 | Systemstufe1 | System level 2 | System level 3 | |
Program P1 | Master | Off | Power level 1 | Power level 1 | Power level 2 |
Slave(s) | Off | Off | Power level 1 | Power level 1 | |
Program P2 | Master | Off | Power level 2 | Power level 1 | Power level 2 |
Slave(s) | Off | Off | Power level 1 | Power level 2 |
Power level 1= 78 m³/h
Power level 2= 92 m³/h
(Details with free outlet)
RLS RC program for mixed system ECA … ipro RC/RCH + ER 100 RC | System level 0 | System level 1 | System level 2 | System level 3 | |
Program P1 | Master ECA | Off | Power level 1 | Power level 1 | Power level 2 |
Slave ECA | Off | Power level 0 | Power level 1 | Power level 1 | |
Slave ER | Off | Power level 1 | Power level 1 | Power level 2 | |
Program P2 | Master ECA | Off | Power level 2 | Power level 1 | Power level 2 |
Slave ECA | Off | Power level 0 | Power level 1 | Power level 2 | |
Slave ER | Off | Power level 1 | Power level 2 | Power level 2 |
ECA: Power level 1 = 78 m³/h / Power level 2 = 92 m³/h
ER: Power level 1 = 35 m³/h / Power level 2 = 60 m³/h / Power level 3 = 100 m³/h
(Details with free outlet)