Fault rectification

Fault finding only by qualified electrician. Call on the services of a qualified electrician any time there is a fault. Repairs should only be carried out by a qualified electrician.

Switch off mains fuse, secure against being accidentally switched back on and position a warning sign.

Fault

Cause, measures

Fan does not switch on.

  • No mains voltage. Check whether the mains fuse has failed. Switch on if necessary.
  • Impeller is blocked. Rectification may only be carried out by a trained specialist: Remove cover. Unlock internal grille or internal shutter via locking hooks. Check impeller and clean if necessary.
  • Humidity control is not working correctly/is faulty with RCH units. Call on the services of a trained specialist.

Motor’s thermal overload protection switches the fan off.

  • Motor too hot. Wait until the motor has cooled down. Cool-down time can be up to 10 minutes. Unit switches back on automatically after cooling down.

Fan doesn’t react to radio commands

  • Fans are not correctly set up. Delete transmitter of all components (delete mode). Delete the transmitter on the RLS RC. Power the fan off briefly. Then re-teach the components.
  • Fans are out of range. Switch repeater mode on at a fan that is within range. If the range is still insufficient, deploy additional repeaters (to be provided by the customer).