Operating programs
- VZC, KVZC, F, KF, B and KB: One of the 4 following operating programs can be set with jumpers J4 and J5.
- H and KH: One of the 4 following operating programs can be set with jumpers J4 and J5. The operating program can only be switched on with a switch (light switch). If this is switched on, it takes priority over the automatic humidity function.
- Program: Comfort (= ex works), Night, Economy and Power
Set the desired operating program with jumpers J4 and J5.
Comfort program
- Power level 1 during room use, power level 2 during overrun time.
- J4 bridged, J5 bridged.
Night program
- Power level 2 during room use, power level 1 during overrun time.
- J4 open, J5 open
Economy program
- Power level 1 during operation and overrun time.
- J4 open, J5 bridged
Power program
- Power level 2 during operation and overrun time.
- J4 bridged, J5 open