Fault rectification

Fault finding only by qualified electrician. Call on the services of a qualified electrician any time there is a fault. Repairs should only be carried out by a qualified electrician.

Fault

Cause, measures

Fan does not switch on.

  • VZ or F units: Wait for start delay (approx. 50 seconds).
  • No mains voltage. Check whether the mains fuse has failed. Switch on if necessary.
  • Impeller is blocked. Rectification may only be carried out by a trained specialist: Unlock and remove the internal grille/shutter frame. Check impeller and clean if necessary.

Fan does not switch off.

  • VZ or F units: Wait for overrun time (approx. 6 minutes).

Motor’s thermal overload protection switches the fan off.

  • Motor too hot. Wait until the motor has cooled down. Cool-down time can take up to 10 minutes. Unit switches back on automatically after cooling down.

Lamellae do not open or close for K units.

  • Lamellae very dirty or blocked. Clean lamellae. Check whether there are any objects between the lamellae. If so, remove them.