Technical data
Ambient conditions
- Permissible maximum temperature of air medium +40 °C.
- Sufficient supply air intake must be ensured during operation with air-ventilated fireplaces. The maximum permitted pressure difference per residential unit is 4 Pa.
- Store unit only in a dry location (-20 to +50 °C).
Technical data for EN.. and ENR..
For more technical data → rating plate.
For characteristic curves → www.maico-ventilatoren.com.
Rated voltage | 230 V AC |
Power frequency | 50 Hz |
Sound pressure level | 45 to 57 dB(A), depending on unit variant |
Degree of protection | IP 44 |
Nominal power EN 20 / EN 25, EN 31 ENR 20 / ENR 25, ENR 31 |
30 W / 39 W / 76 W 42 W / 48 W / 76 W |
Weight | Up to 4.7 kg, depending on unit variant |
Dimensions
| A | B | C | D | E |
---|---|---|---|---|---|
EN 20, ENR 20 | 55 | 103 | 212 | 320 | 268 |
EN 25, ENR 25 | 55 | 103 | 266 | 370 | 315 |
EN 31, ENR 31 | 60 | 126 | 320 | 445 | 375 |