Wall installation, second room
Installation video for ER EC second room connection
- Cut out housing segment on the marking using a knife.
The unit will be damaged/function will be impaired by incorrect air if the installation socket is inserted incorrectly [11.1].
Degree of protection is no longer guaranteed.
- Correctly insert installation socket up to stop. This must audibly engage.
- Place installation socket in housing. The edge of the socket must click into place on the wall of the housing.
- Install housing as described above for single room.
- Connect suction duct with installation socket sealed for ventilation.
- Produce fixing holes for adapter and insert dowels.
- Connect adapter to suction duct, e.g. with cold-shrink tape.
- Secure adapter to the wall.
- Insert filter mat and locate the internal grille in the correct position.
11.1 | Installation socket for second room extraction, DN 75/80 |
11.2 | Adapter |
11.3 | Internal grille |
11.4 | G2 filter mat |
12 | Suction duct, second room connection: AFR 75/AFR 80 flexible aluminium duct |
31 | UPM 60/100 or ER-UPM mounting support |
S | Housing segment |