ECA-DR: installation on wall/ceiling with flat channel
Only connect the fan to a permanent electrical installation. For permissible cable types, see ECA 100 iproinstallation instructions.
When installing in thin wooden or plasterboard walls, ensure that the wall has sufficient load-bearing capacity.
To optimise the immersion depth of the fan in the flat channel angle piece, remove a spacing frame if necessary (only if the wall thickness is sufficient).
Press the required number of spacing frames into each other until they audibly click into place and form a block.
Push the power cable through the 10.5 mm hole in the spacing frame block.
Attach the spacing frame block to the wall or ceiling using the four 100 mm screws supplied. Use the inner Ø 5.5 mm holes. Use mounting material suitable for the surface.
Fit ECA 100 ipro. Ensure that the cable grommet is correctly installed. Proceed as described in the previous chapter.