Technical data

Rated voltage

230 V AC

Power frequency

50 Hz/60 Hz

Maximum loading
(inductive load)

0.4 A

Maximum loading
(ohm resistive load)

10 A

Max. backup fuse

25 A (gL)

Max. power loss

approx. 6 W

Radio interference suppression (EN 55011)

VDE 0875, interference level N

Max. cable cross-section

6 mm²

Max. cable cross-section for TB/auxiliary switch

2.5 mm²

Degree of protection

IP 55

Protection class

II

Type of installation

Surface-mounted

Weight

0.6 kg

Dimensions (WxHxD)

80 x 135 x 96.5 mm

Ambient temperature

-25 … 40 °C