PP 45 RC service menu

Bold

Factory settings

LED flashes quickly

LED flashes slowly

LEDs

Parameters

Set value

Setting / description

The orange operating mode LED flashes 1x per cycle

Supply air mode

0
1
2

Supply air mode without overrun
Supply air mode with overrun of 6 min. (red LED 1x)
Supply air mode with overrun of 15 min. (red LED 2x)

Supply air mode for exhaust air units (e.g. ER.../ECA...) is released and parameterised here.

Notice: The choice of overrun (6 or 15 minutes) depends on the unit.

ER 60 (0  min.), ER 60 VZ (6 min.), ER 60 VZ 15  (15 min.).

The orange operating mode LED flashes 2x per cycle

Sensor

0
1

Inactive
active (red LED 1x)
The PP 45 HYI internal humidity sensor is activated here. This sensor can be retrofitted as an option (only in master unit) and is not included in the scope of delivery.

The orange operating mode LED flashes 3x per cycle

Ventilation levels

0
1

Ventilation level “0” possible
Ventilation level “0” blocked
(red LED 1x)
If ventilation level “0” is set to blocked, the ventilation units cannot be switched off at this control. The units then run with at least ventilation level 1

The blue operating mode LED flashes 1x per cycle

Duration of
intermittent ventilation/
ventilation level

1
2
3

10 minutes (red LED 1x)
30 minutes (red LED 2x)
60 minutes (red LED 3x)
The duration of the intermittent ventilation (level 5) and the duration of the ventilation level, when overriding the demand-driven operation, are parameterised here (factory setting 30 minutes)

Bold

Factory settings

LED flashes quickly

LED flashes slowly

LEDs

Parameters

Set value

Setting / description

The blue operating mode LED flashes 2x per cycle

Sleep function

1
2
3

30 minutes (red LED 1x)
60 minutes (red LED 2x)
90 minutes (red LED 3x)
The duration of the sleep function (level 0) is parameterised here
(factory setting 60 minutes).

The blue operating mode LED flashes 3x per cycle

Filter runtime

1
2
3
4

2 months (red LED 1x)
3 months (red LED 2x)
6 months (red LED 3x)
Reset filter runtime (red LED 4x)
.The filter runtime is parameterised here (factory setting 6 months).

The blue operating mode LED flashes 4x per cycle

Single-room ventilation unit

1
2

Operation in pairs (red LED 1x)
single-room ventilation unit (red LED 2x)
The configuration of the PP 45 RC unit, as a single-room ventilation unit, is released here.
Recommendation: PP 45 RC-Do not use units as single-room ventilation units, because the DIBt approval will thereby cease to apply. If a PP 45 RC is used as a single-room ventilation unit, the volumetric flow compensation must be undertaken using exterior wall air openings. This has a negative impact on the degree of heat provision.