PP 45 RC service menu
Bold | Factory settings |
LED flashes quickly | |
LED flashes slowly |
LEDs | Parameters | Set value | Setting / description | |
| The orange operating mode LED flashes 1x per cycle | Supply air mode | 0 | Supply air mode without overrun Supply air mode for exhaust air units (e.g. ER.../ECA...) is released and parameterised here. Notice: The choice of overrun (6 or 15 minutes) depends on the unit. ER 60 (0 min.), ER 60 VZ (6 min.), ER 60 VZ 15 (15 min.). |
| The orange operating mode LED flashes 2x per cycle | Sensor | 0 | Inactive |
| The orange operating mode LED flashes 3x per cycle | Ventilation levels | 0 | Ventilation level “0” possible |
| The blue operating mode LED flashes 1x per cycle | Duration of | 1 | 10 minutes (red LED 1x) |
Bold | Factory settings |
LED flashes quickly | |
LED flashes slowly |
LEDs | Parameters | Set value | Setting / description | |
| The blue operating mode LED flashes 2x per cycle | Sleep function | 1 | 30 minutes (red LED 1x) |
| The blue operating mode LED flashes 3x per cycle | Filter runtime | 1 | 2 months (red LED 1x) |
| The blue operating mode LED flashes 4x per cycle | Single-room ventilation unit | 1 | Operation in pairs (red LED 1x) |