Radio-controlled operation (EnOcean)
Radio-controlled operation (EnOcean) is implemented as follows:
-
Purely radio-controlled system
DS 45 RC + PP 45 RC / PP 45 RC PPB 30 RC -
Combination system
RLS 45 K + max. 6 PP 45 K / PP 45 O or
RLS 45 K+ max. 3 PPB 30 O / PPB 30 K -
Combination system
PP 45 EO + PP 45 RC / PPB 30 RC
Further characteristics
- For range of radio components → Technical data.
- For possible radio combinations → Overview figures of control concepts.
- The radio mode (EnOcean) is activated by the specialist installer. Once radio operation has been activated, you can teach-in/delete EnOcean radio components directly on the ventilation unit.
- The repeater function (signal amplification) is available for EnOcean radio sensors and radio switches with EEP protocol.
- PP 45 and PPB 30 ventilation units can only amplify the signals for the EnOcean radio sensors and radio switches (EEP protocol). No signal amplification is possible between the PP 45 and PPB 30 ventilation units because the protocol is internal to the unit.