Teaching-in unit pairs
- Remove the front cover on the ventilation units.
- Switch the master ventilation unit (receiver) into teach-in mode To do so, press the TEACH button on the master for 2 seconds. All 3 LEDs flash, teach-in mode is activated.
- Now, a teach-in telegram must be received within 120 seconds or the teach-in mode is terminated.
- Activate the teach-in mode on the slave ventilation unit (transmitter). Press the TEACH button here for 2 seconds. All 3 LEDs flash.
- Switch slave unit into send-teach mode. To do this, press TEACH button briefly 1x. The 3 LEDs on the slave flash once and then switch off (periodic process).
- Press TEACH button on the slave (> 2 seconds) until the LEDs on the slave briefly light up once and then go out.
- The teach-in telegram is sent.
When a teach-in telegram is correctly received, teach-in mode is exited by the receiver and transmitter. If the master unit is still in teach-in mode (3 LEDs flashing), the teach-in telegram from the slave unit has not arrived → Repeat process.
- Before putting on the front cover of the PP 45 RC, the shutter must always be open. To do this, switch on the PP 45 RC.
- Fit front cover for internal housing on the units such that it locks into the safety catches.
- Run function test.