Teaching-in PP 45 ACT EnOcean wireless actuator
With the PP 45 ACT EnOcean actuator, radio-controlled PP 45 RC PushPull units can be combined with wired exhaust air units (ECA, ER).
The EnOcean actuator can be used as a normal light switch. The wired exhaust air units (ECA, ER) are switched on at the push of a button.
At the same time, a radio telegram is sent to the PP 45 RC master unit. The PP 45 RC units (master + slave) provide the required supply air at the exhaust air units.
Teaching-in on the PP 45 RC unit (master unit only) is the same as teaching-in a sensor.
Through the master-slave network, both PP 45 RC units provide 30 m³/h of supply air during the “Supply air for exhaust air units” function.
We therefore recommend using the PP 45 ACT only with two PP 45 RC radio-controlled units. The actuator must only be taught-in at the master unit.
Teaching-in PP 45 ACT on the PP 45 RC master unit
- Electrically connect PP 45 ACT → Installation instructions for final installation kit, connection diagrams in the appendix.
- Check the functions on the exhaust air fan. If these function correctly, switch off the exhaust air unit with the PP 45 ACT.
- Set PP45 RC master unit to teaching mode.
- Press the T4 button once on the PP 45 ACT. The exhaust air unit switches on. The units are now taught-in to each other.
- Check the functions on the exhaust air fan. If these function correctly, switch off the exhaust air unit with the PP 45 ACT