Service mode
For detailed information on the service mode → Shell and final installation kit instructions. In all cases, these instructions should be read before you change the system parameters.
- In service mode, activate the components connected to the room air controls.
- Activate the EnOcean or ModeBus interface if RC ventilation units are connected and/or a building control system connection is to be established.
- If room air controls connected in parallel are released, service mode can be called up from each control.
- Activate more room air controls, power units, sensors and EnOcean modules on RLS master. More RLS must be parameterised and addressed as slaves via service mode.
- Systems with an RLS 45 K control can also be configured using a PC (USB) + commissioning software.
- The PP 45 EO EnOcean module can only be taught-in with the commissioning software + RLS 45 K.