Changing air filters

Change the unit filters when the filter change indicator is on.

A pending filter change is displayed on a main control unit (if the status display is switched on under basic settings). On the RLS 1 WR single control unit, the LED of ventilation level II flashesregularly at longer intervals.

Illustration example WS 120 Trio LRV

1

Unit filter sticker

2

F7 fine dust filter (pollen filter)

3

Filter cover

4

Unit filter sticker

5

M5 unit filter

6

Filter cover

Recommendation: Change the two unit filters together.

  1. Remove the filter cover from the filter positions marked with the stickers.
  2. Pull the F7 or M5 filter out of the ventilation unit.
  3. Carefully slide the new filters into the filter shaft. Do not press filter in (cellulose). Only press in at reinforced corners. Make sure that the air direction arrow is facing downwards.
  4. Close the filter openings with the filter cover.
  5. Reset filter change interval.
    For single RLS 1 WR control units in solo operation: Press key NOTE! ▲ and NOTE! ▼ at the same time for 2 seconds. The 3 LEDs flash briefly. If resetting prematurely, press the keys at the same time for 10 seconds.
    On a main control unit (RLS T2 WS, web tool, app) click on the message and confirm the filter change with changed. Also confirm a premature filter change with changed.
  6. Dispose of the air filter according to local regulations.