2) Main board WS 300 Flat
Wiring diagram for main board
A | WS 300 Flat ventilation unit |
A1 | Electronics slide-in module |
A2 | Controlled domestic ventilation control |
B1 | Control unit, RLS 1 WR |
B2-B5 | Parallel connection max., 5 RLS 1 WR |
BT1 | Control unit, RLS T1 WS / RLS T2 WS |
BT2 | Design control unit, RLS G1 WS |
W1 | 230 V AC connection cable |
W2 | Shielded control cable, RLS 1 WR (provided by customer), e.g. LIYY 6 x 0.34 mm² |
W2.1 | Shielded control cable (provided by customer) Room air control, RLS T1 WS / RLS T2 WS / RLS G1 WS, z. B. LIYY 4 x 0,34 mm² |
W5 | Connection cable for preheating register |
W7 | Connection cable for bypass motor |
M1 | Exhaust air/outgoing air fan |
M2 | Outside air/supply air fan |
M3 | Bypass motor |
T-LET | Temperature sensor at air inlet for outside air |
T-OGA | Temperature sensor for outgoing air |
T-SA | Temperature sensor for supply air |
S-EA | Combination sensor for exhaust air |
Further connection options
W2.1 | Connection cable RLS T1 WS / RLS T2/WS / / ModBus, e.g. LIYY 4 x 0.34 mm² |
W3 | Connection cable (provided by customer) for external safety device with potential-free contact 12 V/2 A |
W4 | Connection cable (provided by customer) for external safety device with potential-free contact: 230 V/16 A |
W6 | Connection cable (provided by customer) for multifunction contact. Potential-free relay contact 230 VAC / 5 A, 30 VDC / 5 A |
W8 | Connection cable (provided by customer) for external sensors |
W9 | Connection cable (provided by customer) for external sensors |
XO1 | Slot for optional EnOcean / KNX communication plug-in module |
ZP1 | 230 VAC connection terminals for wiring additional circuit board ZP 1 |
USB | USB service port |
Ethernet | Network interface (LAN) |