Temperature

Actual room temperature

For current actual temperatureOverview menu or Temperature/Room temperature. Depending on the setting under Basic settings/Room sensor configuration either the Exhaust air temperature in the unit or the Temperature at a KNX operating unit/bus sensor is displayed.

For adjusting the actual room temperature values in the event of sensor measurement deviations→ Room temperature adjustment (AIR@home web tool).

Setpoint room temperature

The setpoint temperature of the room (living area temperature) can only be set if the ventilation unit is combined with a supply air heat register or an optional supplementary heating. The supplementary heating must be connected to the unit control.

The room setpoint temperature can be set in 0.5 °C steps, setting range 18 °C to 25 °C. After adjusting the room setpoint temperature, the ventilation unit automatically adjusts the actual temperature to the desired setpoint temperature.