WS 75 Powerbox H
I | Outside air: Air supplied to the unit |
II | Supply air: Supply air in living areas |
III | Exhaust air: Exhaust air from living areas |
IV | Outgoing air: Outgoing air to outside |
3 | Exhaust air combi sensor humidity/temperature. Optional accessories: Combi sensor for VOC/humidity/temperature Combi sensor for CO2/humidity/temperature |
4 | Air filter for exhaust air, ISO 16890 coarse 65% (filter class G4) |
5 | Enthalpy heat exchanger (for transferring heat and humidity between exhaust air and supply air) |
6 | Optional: Pollen filter, ISO 16890 ePM1 55% (filter class F7) |
7 | Air filter for outside air, ISO 16890 coarse 65% (filter class G4) |
8 | Electronics compartment with main circuit board A1 (unit control/interface X01, optional KNX or EnOcean wireless plug-in module) |
9 | Operating unit/antenna cable feedthrough |
10 | USB port: PC/notebook connection |
11 | Supply air temperature sensor |
12 | Optional: Supply air heat register/supplementary heating, WS 75 NH for heating the supply air |
13 | Outgoing air temperature sensor |
14 | Exhaust air/outgoing air fan |
15 | Outside air temperature sensor (frost protection) |
16 | Outside air/supply air fan (fresh air) |
S | EPP sealing plugs WS 75 S (3x) for supply air and exhaust air ducts |
T | Rating plate |
SN | Serial number |