System components

Fig. 2 Schematic structure of geniovent.x 600 – 900 S ventilation system

 

1

Front door (comprising 2 parts) with twist/turn catch
Function: Swivel-mounted front door. Simple opening and closing via twist/turn catches for changing filters. Access to control circuit board from inside.

2

Top box, sample illustration (optional)
Function: Used to deflect/connect the 4 air ways.

3

RLS 1 WR control panel
Function: Control panel suited to the geniovent.x ventilation unit. On/Off, 4 levels, filter replacement and fault display.

4

External CO2 sensor (optional) or external VOC sensor (optional)
Function of CO2 sensor (optional): Sensor for detection of carbon dioxide CO2.
Function of VOC sensor (optional): Sensor for registering volatile organic compounds (VOCs).

5

Motion sensor (optional)
Function: for detecting room occupancy.

6

Exhaust air filter, filter class ePM 10 60% (M5)
Function: Filters coarse dirt out of the exhaust air

7

Electrical terminal box with control circuit board
Function: Central control unit of ventilation system

8

Outgoing air fan
Function: Conveys the used air to the outside.

9

Bypass
Function: Used to bypass the heat exchanger.

10

Heat exchanger
Function: In the heat exchanger, heat is transferred between the exhaust air and supply air flows.

11

Outside air fan
Function: Conveys fresh air into the living area.

12

Outside air filter, filter class ePM1 55% (F7)
Function: Filters the finest contamination, e.g. pollen, out of the outside air.

13

Condensate tank*
Function: Condensate collects in the stainless steel condensate tank.

14

Condensate lift pump*
Function: Pumps the collected condensate out of the ventilation unit
(hose in outgoing air socket).

15

Preheater
Function: Prevents the heat exchanger from icing over at low outside air temperatures.

16

Outside air, outgoing air shutters
Function: To close off the unit when stationary.

17

Connection cable
Function: Cable for external connections, e.g. voltage, operation, BUS, Ethernet and USB.

* Only for versions with cross-counterflow heat exchanger (variant G).