Axial roof fan

DZD 60/4 BL

No longer available for delivery
Article number: 0087.0629
Manufacturer: MAICO
Axial roof fan, horizontal air outlet, DN 600, three-phase AC
Application examples: Production facility, Workplace, Commercial premises, Restaurant, Showroom
Product data sheet
DZD 60/4 BL IM0009965.PNG Axial roof fan, horizontal air outlet, DN 600, three-phase AC

Characteristic curve

DZD 60/4 BL - Characteristic curve

Dimensioned drawing

DZD 60/4 BL - Dimensioned drawing [mm]

Technical data

DZD 60/4 BL - Technical data

Article DZD 60/4 BL
Air flow volume 9.775 m³/h
Air volumenom 5.900 m³/h / in opt. efficiency
Pressure pfs, nom 168 Pa / in opt. efficiency
Rotating speed nnom 1.330 1/min / in opt. efficiency
Impeller type axial
Speed controllable
Reversing capacity
Type of voltage Three-phase AC
Rated voltage 400 V
Nominal output 1.450 W / in opt. efficiency
Inom 2,3 A / in opt. efficiency
Imax 3,2 A
Degree of protection IP 55
Insulation class F
Mains cable 7 x 1,5 mm²
Installation site Roof
Installation position vertical
Material Sheet steel, galvanised
Weight 54,4 kg
Weight including packaging 62 kg
Nominal size 600 mm
Width with packaging 1.110 mm
Height with packaging 500 mm
Depth with packaging 1.110 mm
Airstream temperature at nominal current -20 °C up to 60 °C
Airstream temperature at IMax -20 °C up to 60 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799876298
Article number 0087.0629
Article DZD 60/4 BL
Total efficiency η 35,2 %
Measurement category C
Efficiency category static
Efficiency level N 40,4
Year of manufacture see rating plate
Manufacturer’s name / official registration number / manufacturer's place of establishment Maico Elektroapparate-Fabrik GmbH / Freiburg registration court, HRB 601233 / Villingen-Schwenningen
Art. No. 0087.0629
PBEP / Air volumeBEP / Pfs, BEP 1,325 kW / 9.080 m³/h / 205 Pa
nBEP 1.325 1/min
Specific ratio ≈ 1
Information about dismantling and disposal see mounting instructions
Information about installation, operation and repairs see mounting instructions
Objects used to measure efficiency which are not described by the measurement category Calculation of energy efficiency without protective grille and roof cowl.
Sound power levelLWA7 94 dB(A)

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA7, S5 (dB(A))

94

LWA7= housing and free inlet sound power level in dB.

Accessories

DZD 60/4 BL - Accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
Control shutter JRE 60 0151.0395 on request
  • On the notes
Servomotor MS 8 0157.0760 on request
  • On the notes
Servomotor MS 8 P 0157.0761 on request
  • On the notes
Protective grille, metal SG 60 0150.0122 on request
  • On the notes
Flexible coupling ELA 60 0092.0273 on request
  • On the notes
Flexible cuff EL 60 0092.0093 on request
  • On the notes
Counter socket GS 60 0055.0175 on request
  • On the notes
Suction nozzle AD 60 0180.0627 on request
  • On the notes
Main switch, service switch HS 3 0157.0736 on request
  • On the notes
Rotary switch DS 10 0157.0410 on request
  • On the notes
Reversing switch W 1 0157.0101 on request
  • On the notes
Reversing switch WU 1 Discontinued product 0157.0102 on request
  • On the notes
Contactor US 16 T 0157.0769 on request
  • On the notes
5-step transformer TR 6,6-2 0157.0150 on request
  • On the notes
5-step transformer, control cabinet TR 6,6 S-2 0157.0153 on request
  • On the notes
5-step switch for TRE...S -2/ TR...S-2 5-step transformers DSS 20 0157.0750 on request
  • On the notes
Thermostat THR 10-1 0157.0191 on request
  • On the notes
Thermostat TH 10 0157.0764 on request
  • On the notes
Thermostat TH 16 0157.0748 on request
  • On the notes
Air flow monitor LW 9 0157.0779 on request
  • On the notes
Hygrostat HY 230 0157.0126 on request
  • On the notes
Hygrostat HY 230 I 0157.0127 on request
  • On the notes
Air quality controller EAQ 10/1 Discontinued product 0157.0777 on request
  • On the notes
Roof socket for flat roofs SO 60 0093.0365 on request
  • On the notes
Thermostat THR 10 No longer available for delivery 0157.0774 on request
  • On the notes
Counter flange GF 60 No longer available for delivery 0056.0009 on request
  • On the notes
5-step transformer, control cabinet TR 6,6 S No longer available for delivery 0157.0743 on request
  • On the notes
Temperature control system, power module ATL 6 No longer available for delivery 0157.0758 on request
  • On the notes
Hygrostat HY 5 No longer available for delivery 0157.0123 on request
  • On the notes
Hygrostat HY 10 AP No longer available for delivery 0157.0358 on request
  • On the notes
Hygrostat HY 10 UP No longer available for delivery 0157.0357 on request
  • On the notes

Product description

Productdescription

DZD 60/4 BL

short description

Axial roof fan, horizontal air outlet, DN 600, three-phase AC

Product description

Brief description

  • Housing, base plate, intake nozzle and rain protection cover made of galvanised sheet steel.
  • Galvanized protective grille on the discharge side, protection against accidental contact in accordance with DIN EN ISO 13857.
  • Sturdy eyebolts enable transport by crane.
  • 8-blade impeller made of glass fibre reinforced polyamide.
  • Fans meet the requirements of the European Ecodesign Directive (EC) No.327/2011 Directive 2009/125/EC.
  • Vibration-free running due to dynamically balanced impeller and motor (shaft-rotor), according to quality class 6.3, DIN ISO 1940, part 1.
  • High efficiency on the ventilation side, low operating noise.
  • Increased durability due to high-quality materials such as quiet ball bearings.
  • Fans are maintenance-free.
  • Can be switched to ventilation or air extraction with separate switch (exception EZD ... E).

Air flow direction

  • The air flow direction is marked.
  • Standard exhaust air mode, air flow direction with air blown across motor.

Motor

  • Asynchronous motor.
  • Reversible. Exception: Fans with shaded-pole motors (".../E").
  • Thermal overload protection as a standard feature.

Three-phase AC motor

  • Type series: DZD.
  • Asynchronous motor.
  • Rated voltage 400 V, 50 Hz.
  • Degree of protection for DZD ... D IP 54.
  • Degree of protection for DZD ... B IP 55.
  • Speed-controllable. Units can be switched in steps with an optional 5-step transformer.
  • Reversible.
  • Reversing mode: The volumetric flow is reduced by approx. 35 % with abnormal air flow direction.
  • Thermal overload protection as a standard feature. Exception: For type DZD 25/4 D (motor protection switch is provided by the customer).
  • Potential-free terminal connections, which must be connected, e.g., to an MV 25-1 motor protection switch or the control circuit of a contactor.

Electrical connection

  • Connecting cable, approx. 1.7 m long.

Safety information

  • The fan may be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN ISO 13857, e.g., with Maico SG protective grille.
  • A proper fixed installation in a horizontal installation position, a permanent electrical supply cable and correct air supply via shaft or duct is stipulated.

Special versions

  • The following special versions are available on request, at an extra cost:
    • Special voltages and frequencies.
    • Fans with enhanced anti-corrosion protection.
    • Impellers made of aluminium.
  • Information on operation at temperatures occasionally below -20°C available upon request.
  • If operating with frequency converters, the factory must be consulted.
  • Feasibility must be checked in each case.

Table of contents

Wiring diagram

DZD 60/4 BL - Wiring diagram

DZD...BL standard (counter-clockwise, 1 speed)

SC - Protection circuit

TK - Thermal contact



DZD...BL standard with MV 25 motor protection switch


DZD...BL with MV 25 motor protection switch and TR... 5-step transformer


DZD...BL with TRV... 5-step transformer


Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings