- Each PP 45 RC / PPB 30 RC ventilation unit is fitted with a radio module.
- RC units are operated with a DS 45 RC radio switch. This can be simply glued to the installation location on the wall.
Installation location: Do not mount receiver, with internal antenna, on wall side of transmitter.
- Alternatively, wired combination systems can also be used with EnOcean module PP 45 EO. These are then operated using the RLS 45 K control.
- The radio system can be expanded with a PP 45 ACT single channel radio actuator for the `Supply air function´ for exhaust air units. For connection → Radio actuator installation instructions.
Master-slave operation
- With radio-controlled systems, associated PP 45 unit pairs work in master-slave mode.
- Slave units (RC units, radio sensors, radio switches etc.) are taught-in on the master unit. The master unit is then responsible for handling with the slave unit → Radio components which can be taught-in (EEP).
- Only one slave unit can be assigned to each master ventilation unit.
- Slave ventilation units are connected to the master.
- Other components (radio sensors, radio switches etc.) are only taught-in on the master unit.
- To teach-in EnOcean components → PP 45 / PPB 30 operating instructions.