Transport
WARNING
- Danger to life if the centrifugal blower falls with transport equipment/lifting gear which are not permissible or are incorrectly attached. Depending on the product family and type, the centrifugal blower can weigh up to 130 kg. For heavy equipment, use a lifting or hoisting device suitable for the total weight. Observe applicable safety and accident prevention regulations.
- Do not load sensitive unit components during transport.
- Observe the centre of gravity (middle) during transport.
- For transport and storage, observe the technical data → installation and operating instructions.
- Observe the maximum permitted loading capacity for lifting gear and transport equipment.
- Wear protective gloves, when working with components with sharp edges, to avoid cuts.
- Only lift heavy centrifugal blower with several people, especially in case of ceiling installation. For unit weight → rating plate.
- Do not stand under a suspended load.
- Check the centrifugal blower for transport damage before installation. Do not commission a damaged unit.