RLS 1 WR control panel
Solo mode only possible if no RLS T1 SYS is connected. Function not available with air@home APP or air@home web tool.
Parameters: Single control unit: RLS 1 WR control panel
Setting value: Solo, Auxiliary, Inactive/Sensor, Digital/Building control system
Solo: Ventilation unit is operated with the supplied RLS 1 WR control panel + maximum of 4 optional control panel units.
Auxiliary: Ventilation unit is operated with an optional RLS T1 SYS comfort control panel + maximum of 5 optional control panels.
Inactive/Sensor: The connections are needed for extra sensors (sensor 3 and 4). Function only if no control panel is connected.
Digital/Building control system: A 3-level single BCS (building control system) circuit (e.g. KNX) can be constructed via an actuator for adjusting the ventilation level.