Axial duct fan

DZL 60/4 B

No longer available for delivery
Article number: 0086.0092
Manufacturer: MAICO
Axial duct fan, DN 600, three-phase AC
Application examples: Machine extraction unit, Workplace air extraction system, Workshop, Foreman's office, Production site
Product data sheet
DZL 60/4 B IM0014274.PNG Axial duct fan, DN 600, three-phase AC

Characteristic curve

DZL 60/4 B - Characteristic curve

Dimensioned drawing

DZL 60/4 B - Dimensioned drawing [mm]

Number of flange holes: 16

Technical data

DZL 60/4 B - Technical data

Article DZL 60/4 B
Model Stabiliser
Air flow volume 14.450 m³/h
Speed controllable
Reversing capacity
Frequency 50 Hz
Imax 3,6 A
Degree of protection IP 55
Pole-changeable
Mains cable 7 x 1,5 mm²
Installation position vertical / horizontal
Material Sheet steel, galvanised
Weight 39,6 kg
Weight including packaging 43 kg
Nominal size 600 mm
Width with packaging 780 mm
Height with packaging 430 mm
Depth with packaging 780 mm
Airstream temperature at nominal current 60 °C
Airstream temperature at IMax -20 °C up to 60 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799860921
Article number 0086.0092
Article DZL 60/4 B
Total efficiency η 45,4 %
Measurement category D
Efficiency category total
Efficiency level N 51
VSD necessary No
Year of manufacture see rating plate
Manufacturer’s name / official registration number / manufacturer's place of establishment Maico Elektroapparate-Fabrik GmbH / Freiburg registration court, HRB 601233 / Villingen-Schwenningen
Art. No. 0086.0092
PBEP / Air volumeBEP / Pfs, BEP 1,33 kW / 10.120 m³/h / 215 Pa
nBEP 1.350 1/min
Specific ratio ≈ 1
Information about dismantling and disposal see mounting instructions
Information about installation, operation and repairs see mounting instructions
Objects used to measure efficiency which are not described by the measurement category -
IBEP 2,3 A
Sound power levelLWA5 87 dB(A)

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, S1 (dB(A))

32

37

41

45

41

36

27

21

48

LWA2, S2 (dB(A))

36

48

49

61

52

49

38

28

62

LWA2, S3 (dB(A))

38

53

57

63

60

58

48

36

66

LWA2, S4 (dB(A))

43

57

60

67

67

64

55

44

72

LWA2, S5 (dB(A))

48

57

67

73

72

69

61

51

77

LWA5, S1 (dB(A))

37

45

58

54

53

51

41

27

61

LWA5, S2 (dB(A))

37

59

64

68

66

63

55

43

72

LWA5, S3 (dB(A))

38

63

64

75

74

70

64

52

79

LWA5, S4 (dB(A))

42

69

70

77

80

76

70

59

83

LWA5, S5 (dB(A))

44

65

80

85

84

80

74

64

89

LWA6, S1 (dB(A))

48

46

55

59

64

63

65

63

70

LWA6, S2 (dB(A))

50

61

67

71

74

73

75

72

81

LWA6, S3 (dB(A))

57

66

72

79

80

79

79

77

86

LWA6, S4 (dB(A))

62

70

77

84

86

84

83

80

91

LWA6, S5 (dB(A))

65

71

81

90

91

88

87

83

96

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

Product description

Productdescription

DZL 60/4 B

short description

Axial duct fan, DN 600, three-phase AC

Product description

Features

  • Duct sleeve made of galvanised sheet steel, with flanges and guided vanes on both sides.
  • 8-blade impellers made of glass-fibre filled polyamide. Dynamically balanced at two levels, in accordance with performance level 6.3, DIN ISO 1940, Part 1.
  • Flange holes in accordance with DIN 24154, page 2, 7/66.
  • DZL 56/6 B and DZL 56/4 B: Flange holes in accordance with DIN 24145, part 2, 7/90.
  • High degree of protection IP 55.
  • To prevent transfer of vibrations onto the duct system: Use flexible couplings, feet and vibration dampers.
  • Can be fitted in any position.

Motor

  • Asynchronous motor, speed controllable. Exception: Type DZL 40/2 B.
  • Not suitable for ventilating steam-saturated air.
  • EZL / DZL duct fans are non reversible.

Three-phase AC motor

  • DZL series
  • Rated voltage 400 V, 50 Hz.
  • Thermal overload protection as a standard feature. Available on request for pole changeable axial duct fans.
  • Potential-free terminal connection, which must be connected to e.g. an MV 25 full motor protection switch or the control circuit of a contactor.
  • Pole-changeable motors with speed ratios of 8/4 or 4/2 have a Dahlander pole-changing circuit.

Electrical connection

  • Terminal box with cable sleeves fitted on the outside.

Safety instructions

  • The fan can be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN 13857 for fans with a free inlet.

Special versions

  • The following special versions are available at extra cost on request:
    • Special voltages and frequencies.
    • Single-phase motors with thermal contacts or PTC thermistor, with potential-free terminal connections.
    • Condensation drainage holes.
    • Fans with enhanced anti-corrosion protection.
    • Impellers made of aluminium.
  • Information on operation at temperatures occasionally below -20°C available upon request.
  • If operating with frequency converters, the factory must be consulted.
  • Feasibility must be checked in each case.

Table of contents

Wiring diagram

DZL 60/4 B - Wiring diagram

DZL...B standard (counter-clockwise, 1 speed)

SC - Protection contact

TK - Thermal contact



DZL...B standard (anti-clockwise, 1 speed) with MV 25 full protection motor switch


DZL...B standard (anti-clockwise, 1 speed) with TR... 5-step transformer and MV 25 full protection motor switch


DZL... Standard (anti-clockwise, 1 speed) with TRV... 5-step transformer


Predecessor - successor

DZL 60/4 B - Successor

Product type Name Art. No. Action
Axial duct fan DZR 60/4 B 0086.0039
  • On the notes

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings