Small room fan

ECA 150 ipro KH

Article number: 0084.0095
Manufacturer: MAICO
Two-level small room fan, DN 150 with electrical internal shutter and humidity control
Application examples: Kitchen, Utility room, Sauna vestibule, Toilet facilities, Day room
Product data sheet
ECA 150 ipro KH IM0014539.PNG Two-level small room fan, DN 150 with electrical internal shutter and humidity control
ECA 150 ipro KH IM0007250.PNG Two-level small room fan, DN 150 with electrical internal shutter and humidity control

Characteristic curve

ECA 150 ipro KH - Characteristic curve

  1. Performance level 1
  2. Performance level 2

Dimensioned drawing

ECA 150 ipro KH - Dimensioned drawing [mm]

  1. Cable entry for recessed-mounted connection
  2. Cable bushing for surface-mounted connection

Technical data

ECA 150 ipro KH - Technical data

Article ECA 150 ipro KH
Model Humidity control
Air flow volume 200 m³/h / 250 m³/h
Rotating speed 1.672 1/min / 2.189 1/min
Speed controllable
Reversing capacity
SEC average -24,05 kWh/(m²*a)
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Nominal output 18 W / 22 W
Imax 0,11 A
Degree of protection IP X5
Mains cable 3/5 x 1.5 mm²
Installation site Ceiling / Wall
Type of installation Surface-mounted
Installation position any
Material Synthetic material
Colour Traffic white, similar to RAL 9016
Weight 1,5 kg
Weight including packaging 1,77 kg
Shutter integrated
Type of shutter electrical
Nominal size 150 mm
Width 228 mm
Height 228 mm
Depth 123,3 mm
Width with packaging 235 mm
Height with packaging 235 mm
Depth with packaging 200 mm
Airstream temperature at IMax 40 °C
Overrun time 8 min / 17 min / 25 min / Overrun time of 0 min. available when using an optional switch (e.g. light switch)
Start delay 0 s / 50 s / 90 s / 120 s / Start delay available when using an optional switch (e.g. light switch)
Sound pressure level 33 dB(A) / 40 dB(A) / Distance 3 m, Free-field conditions
Packing unit 1 piece
Range A
GTIN (EAN) 4012799840954
Article number 0084.0095

Accessories / Spare parts

ECA 150 ipro KH - Accessories / Spare parts

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Spacing frame ECA15-EMA16 0092.0251 on request
  • On the notes

General accessories

Product type Name Art. No. Price*(EUR) Action
Roof outlet DF - - -
Roofing tile DP - - -
Mounting clamp BS - - -
Rain protection grille RG - - -
Roofing tile DP - - -
Shell kit PP 45 RS New development 0093.1751 on request
  • On the notes
Masonry block MS 160 New development 0058.0168 on request
  • On the notes
Shutter AP 150/1 0059.0996 on request
  • On the notes
External grille SG 150/1 0059.0997 on request
  • On the notes
Wall sleeve WH 150 0059.1050 on request
  • On the notes
Outside air opening ALD 10 0152.0054 on request
  • On the notes
Outside air opening ALD 125 Discontinued product 0152.0067 on request
  • On the notes
Outside air opening ALD 125 VA Discontinued product 0152.0068 on request
  • On the notes
Outside air opening ALD 160 Discontinued product 0152.0069 on request
  • On the notes
Outside air opening ALD 160 VA Discontinued product 0152.0070 on request
  • On the notes
Door ventilation grille MLK 30 white 0151.0123 on request
  • On the notes
Door ventilation grille MLK 45 white 0151.0126 on request
  • On the notes
Flexible aluminium duct AFR 150 0055.0093 on request
  • On the notes
Radio switch XS 1 No longer available for delivery 0157.0344 on request
  • On the notes
Radio receiver XE 1 No longer available for delivery 0157.0343 on request
  • On the notes
Shutter AP 150 No longer available for delivery 0059.0952 on request
  • On the notes
External grille SG 15 No longer available for delivery 0059.0904 on request
  • On the notes

Spare parts

Product description

Productdescription

ECA 150 ipro KH

short description

Two-level small room fan, DN 150 with electrical internal shutter and humidity control

Product description

Model with automatic humidity control

  • Barrier-free product as the fan switches itself on and off via the humidity sensor.
  • Switch-on humidity does not have to be set. Fan monitors the room humidity.
  • Automatic air extraction depending on room humidity, at level 1 and 2.
  • Can be operated without a switch, can also be switched using a separate switch as option.
  • Start delay can be set to different levels using easily accessible switches (only if controlled using switch): 0/50/90/120 sec.
  • Overrun time can be set to different levels using easily accessible switches: 8/17/25 min. An overrun time of 0 min can only be set for the control using a separate switch.
  • The time set is displayed using LEDs during the setting.
  • Concealed inlet, with electrically operated internal shutter.
  • Not speed-controllable.

Operating programs

  • Can be adjusted using jumper in unit.
  • Comfort program (preset)
    • User present: Level 1
    • Overrun time: Level 2
  • Demand program
    • User present: Level 2
    • Overrun time: Level 1
  • Economy program
    • User present: Level 1
    • Overrun time: Level 1
  • Power program
    • User present: Level 2
    • Overrun time: Level 2

Features

  • Intelligently programmed small room fan for very demanding requirements.
  • 2 performance levels.
  • Designer cover conceals the inlet.
  • For air extraction.
  • Combines large air volumes with high pressure.
  • With VDE GS symbol.
  • IP X5 degree of protection for safety in the bathroom.
  • Protection class II.
  • Thermal overload protection.
  • Suitable for continuous operation.
  • Colour: traffic white, similar to RAL 9016.
  • Housing made of impact resistant plastic material.

Motor

  • Energy-saving robust motor with ball bearings, maintenance-free.
  • Suitable for continuous operation.

Mounting information

  • Compatible with ECA predecessor models DN150, because recessed screw holes and cable entry are in the same place.
  • Wall and ceiling installation is possible

Electrical connection

  • Electrical connection can be either surface- or recessed-mounted.

Safety instructions

  • All ECA 150 ipro units can be used in protection area 1 in accordance with DIN VDE 0100-701.
  • For details see planning instructions.

Table of contents

Wiring diagram

ECA 150 ipro KH - Wiring diagram





Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings