Fan insert

ER 60 I

Article number: 0084.0105
Manufacturer: MAICO
Fan insert with cover and filter for installation in recessed-mounted housings, air volume 62 m³/h, with... more information
Application examples: Bathroom, Kitchen, Multiple family unit, Day room, Dining room
Product data sheet
ER 60 I IM0009919.PNG Fan insert with cover and filter for installation in recessed-mounted housings, air volume 62 m³/h, with interval control and time delay switch (start delay 50 seconds, overrun time 10 minutes, interval 1 to 15 hours)
ER 60 I IM0008446.PNG Fan insert with cover and filter for installation in recessed-mounted housings, air volume 62 m³/h, with interval control and time delay switch (start delay 50 seconds, overrun time 10 minutes, interval 1 to 15 hours)
ER 60 I IM0007254.PNG Fan insert with cover and filter for installation in recessed-mounted housings, air volume 62 m³/h, with interval control and time delay switch (start delay 50 seconds, overrun time 10 minutes, interval 1 to 15 hours)

Characteristic curve

ER 60 I - Characteristic curve

Dimensioned drawing

ER 60 I - Dimensioned drawing [mm]

ER fan insert with recessed-mounted housing ER-UP/G or ER-UPD

ER 60 I - Dimensioned drawing [mm]

ER fan insert with recessed-mounted housing ER-UP/G or ER-UPD and second room connection

Technical data

ER 60 I - Technical data

Article ER 60 I
Model Interval control
Air flow volume 62 m³/h
Rotating speed 1.250 1/min
Air direction Air extraction
Speed controllable
SEC average -3,43 kWh/(m²*a)
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Power consumption 21 W
Imax 0,16 A
Degree of protection IP X5
Mains cable 5 x 1,5 mm²
Installation site Wall / Ceiling
Type of installation Recessed-mounted
System type Decentralised
Material Synthetic material
Colour Traffic white, similar to RAL 9016
Weight 1,52 kg
Weight including packaging 1,8 kg
Filter class ISO Coarse 30 % (G2)
Air outlet direction at side
Width 250 mm
Height 250 mm
Depth 150 mm
Width with packaging 280 mm
Height with packaging 280 mm
Depth with packaging 155 mm
Airstream temperature at IMax 40 °C
Overrun time 10 min / Overrun time available when using an optional switch (e.g. light switch)
Start delay 50 s / Start delay available when using an optional switch (e.g. light switch)
Sound pressure level 36 dB(A) / Specifications in accordance with DIN 18017-3 at an equivalent absorption area AL = 10 m.2
Packing unit 1 piece
Range B
GTIN (EAN) 4012799841050
Article number 0084.0105

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA7, high (dB(A))

40

LWA7= housing and free inlet sound power level in dB.

Accessories / Spare parts

ER 60 I - Accessories / Spare parts

Specific accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
Flexible aluminium duct AFR - - -
Roof outlet DF - - -
Roofing tile DP - - -
Mounting clamp BS - - -
Rain protection grille RG - - -
Roofing tile DP - - -
Outside air opening ALD 10 0152.0054 on request
  • On the notes
Outside air opening ALD 125 Discontinued product 0152.0067 on request
  • On the notes
Outside air opening ALD 125 VA Discontinued product 0152.0068 on request
  • On the notes
Outside air opening ALD 160 Discontinued product 0152.0069 on request
  • On the notes
Outside air opening ALD 160 VA Discontinued product 0152.0070 on request
  • On the notes
Door ventilation grille MLK 30 white 0151.0123 on request
  • On the notes
Door ventilation grille MLK 45 white 0151.0126 on request
  • On the notes
Hygrostat HY 230 0157.0126 on request
  • On the notes
Hygrostat HY 230 I 0157.0127 on request
  • On the notes
Radio switch XS 1 No longer available for delivery 0157.0344 on request
  • On the notes
Radio receiver XE 1 No longer available for delivery 0157.0343 on request
  • On the notes
Outside air opening ALD 10 T No longer available for delivery 0152.0055 on request
  • On the notes
Outside air opening ZE 45 F white No longer available for delivery 0152.0044 on request
  • On the notes

Spare parts

Product type Name Art. No. Price*(EUR) Action
Cover ABD ER 60/100/Centro E059.1017.9001 on request
  • On the notes
Capacitor KS ECA ER E157.0116.0000 on request
  • On the notes
Circuit board PL ER 60 I E101.1014.9403 on request
  • On the notes

Product description

Productdescription

ER 60 I

short description

Fan insert with cover and filter for installation in recessed-mounted housings, air volume 62 m³/h, with interval control and time delay switch (start delay 50 seconds, overrun time 10 minutes, interval 1 to 15 hours)

Product description

Model with interval control

  • The interval control ensures that rooms, that are not used regularly, are ventilated.
  • Time interval adjustable from 1 to approx. 15 hrs.
  • Approx. 10 min. operating time per interval.
  • When operated manually (e.g. by light switch) there is a start delay of approx. 50 sec. and an overrun time of approx. 10 min.
  • Interval control can be switched off.
  • Not speed-controllable.

Features

  • Fan with cover and ISO Coarse 30 % (G2) filter for installation in ER-UP/G, ER-UPD and ER-UPB.... flush-mounted housings
  • For single or second room air extraction using a single fan (exception: H model).
  • Trouble-free filter change without tools.
  • It is possible to rotate the cover by ± 5°, to compensate for housings which have been fitted at an angle.
  • Simple and quick installation of the fan in the housing via the snap-on attachment and the electrical plug connector.
  • Colour: traffic white, similar to RAL 9016.
  • All MAICO ER units have an IP X5 degree of protection and can be installed in area 1 in accordance with DIN VDE 0100-701, even with water jets. For details see planning instructions.
  • Protection class II.
  • The extremely steep characteristic curve shows the high pressure capacity of the ER fans.
  • Robust energy-saving capacitor motor.
  • Motor with thermal overload protection.
  • Maintenance-free, with enclosed ball bearings on both sides.
  • Volumetric flow characteristic curve and air leakage rate checked by TÜV Bayern e.V (German Technical Inspection Agency). Air leakage rate < 0.01 m³/h.
  • Shaft level difference according to DIN 52210-6, tested by IAB Oberursel (The Institute for Acoustics and Building Physics in Germany).
  • With VDE symbol.

Table of contents

Wiring diagram

ER 60 I - Wiring diagram

S1 on (after approx. 50 s)

S1 off (overrun time 6 min.)

Using a 1-pin switch can cause reverse polarity voltages. Combination with an X2 capacitor necessary!



Switching option 1

S1 and S2 on (after aprox. 50 s)

S1 off (overrun time 6 min.)

In addition, the fan can be switched off with switch S2 independent of the room lighting.

Using a 1-pin switch can cause reverse polarity voltages. Combination with an X2 capacitor necessary!



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings