Technical data

ERR 20/1 - Technical data

Article ERR 20/1
Air flow volume 840 m³/h
Rotating speed 2.611 1/min
Impeller type radial
Speed controllable
Reversing capacity
SEC average -10 kWh/(m²*a)
Energy efficiency class F
Type of voltage Alternating current
Rated voltage 230 / 220 V
Frequency 50 Hz/60 Hz
Nominal output 116 W
Imax 0,5 A
Degree of protection IP X4
Insulation class F
Pole-changeable
Installation position vertical / horizontal
Material Sheet steel, powder coated
Housing material Sheet steel, powder coated
Colour Light grey
Weight 4,4 kg
Weight including packaging 5,28 kg
Nominal size 200 mm
Width 370 mm
Height 407 mm
Depth 230 mm
Width with packaging 390 mm
Height with packaging 390 mm
Depth with packaging 300 mm
Airstream temperature at nominal current -20 °C up to 60 °C
Airstream temperature at IMax -20 °C up to 60 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799802754
Article number 0080.0275

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, S1 (dB(A))

15

29

27

31

28

19

9

35

LWA2, S2 (dB(A))

20

38

35

41

39

36

27

13

45

LWA2, S3 (dB(A))

27

40

42

50

49

46

43

29

54

LWA2, S4 (dB(A))

28

42

45

53

53

50

48

35

58

LWA2, S5 (dB(A))

34

43

47

55

56

53

51

38

60

LWA5, S1 (dB(A))

18

34

52

48

45

41

29

16

55

LWA5, S2 (dB(A))

26

38

69

60

57

56

47

37

70

LWA5, S3 (dB(A))

34

42

59

69

67

65

62

50

73

LWA5, S4 (dB(A))

36

45

65

68

71

68

66

55

75

LWA5, S5 (dB(A))

38

47

67

69

73

70

69

58

77

LWA6, S1 (dB(A))

27

34

58

44

43

41

27

14

59

LWA6, S2 (dB(A))

28

38

66

60

56

57

47

35

68

LWA6, S3 (dB(A))

34

42

63

62

65

65

61

48

71

LWA6, S4 (dB(A))

36

45

66

64

68

68

64

53

74

LWA6, S5 (dB(A))

37

47

66

66

70

70

66

56

75

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

Accessories

ERR 20/1 - Accessories

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Fixing cuff ELR 20 0092.0112 on request
  • On the notes
Mounting foot FUR 16S/20/25 0036.0088 on request
  • On the notes
Speed control system DRS 0157.0188 on request
  • On the notes

General accessories

Product type Name Art. No. Price*(EUR) Action
Automatic backflow preventer AVM 20 0093.0006 on request
  • On the notes
Protective grille SGR 20 0150.0126 on request
  • On the notes
Internal grille LGR 32/6 0151.0354 on request
  • On the notes
Internal grille LGR 42/6 0151.0355 on request
  • On the notes
Internal grille LGR 52/6 0151.0356 on request
  • On the notes
Internal grille LGR 62/6 0151.0357 on request
  • On the notes
Internal grille LGR 82/6 0151.0358 on request
  • On the notes
Internal grille LGA 42/12 Discontinued product 0151.0260 on request
  • On the notes
Tubular sound absorber RSR 20 Remaining parts 0092.0316 on request
  • On the notes
Tubular sound absorber RSR 20/50 Remaining parts 0092.0326 on request
  • On the notes
Tubular sound absorber RSR 20-1 0092.0597 on request
  • On the notes
Tubular sound absorber RSR 20/50-1 0092.0604 on request
  • On the notes
Electrical air heater ERH 20-2 0082.0103 on request
  • On the notes
Electrical air heater DRH 20-5 0082.0106 on request
  • On the notes
Electrical air heater with controller DRH 20-6 R 0082.0144 on request
  • On the notes
Water air heater WRH 20-2 0082.0119 on request
  • On the notes
Air filter TFE 20-4 0149.0078 on request
  • On the notes
Air filter TFE 20-7 0149.0053 on request
  • On the notes
Contactor US 16 T 0157.0769 on request
  • On the notes
Cellar dehumidification control AKE 0157.0129 on request
  • On the notes
Speed controller STX 1,5 0157.1561 on request
  • On the notes
Speed controller, distribution board STSX 2,5 0157.1564 on request
  • On the notes
5-step transformer TRE 0,6-2 0157.0157 on request
  • On the notes
Temperature control system DTL 16 P 0157.0825 on request
  • On the notes
Channel sensor FL 30 P 0157.0780 on request
  • On the notes
Room sensor FR 30 P 0157.0781 on request
  • On the notes
Air flow monitor LW 9 0157.0779 on request
  • On the notes
Hygrostat HY 230 0157.0126 on request
  • On the notes
Hygrostat HY 230 I 0157.0127 on request
  • On the notes
CO2 sensor SKD 0157.0345 on request
  • On the notes
Cellar dehumidification control AKE/1 New development 0157.1683 on request
  • On the notes
Air filter TFE 20-5 No longer available for delivery 0149.0062 on request
  • On the notes
Speed controller ST 1 No longer available for delivery 0157.0810 on request
  • On the notes
Speed controller STU 1 No longer available for delivery 0157.0814 on request
  • On the notes
Speed controller, distribution board STS 2,5 No longer available for delivery 0157.0255 on request
  • On the notes
Temperature control system ETL 16 P No longer available for delivery 0157.0824 on request
  • On the notes

Product description

Productdescription

ERR 20/1

short description

Centrifugal duct fan, DN 200, single-phase AC

Product description

Special features

  • Efficient centrifugal duct fan made of powder-coated sheet steel.
  • Suitable for industrial and residential installations.
  • Centrifugal impeller with backwards curved blades.
  • Quiet and powerful.
  • Reduced space requirement due to compact dimensions.
  • For direct installation between ducts, for ventilation or air extraction, depending on the installation position.
  • Round connection sockets on inlet and outlet side adapted to standard ducts.
  • Mounting foot available as accessory.

Air flow direction

  • Airstream and rotational directions are indicated by arrows marked on the fan housing

Motor

  • Single-phase AC motor.
  • External rotor capacitor motor.
  • Operating capacitor in the terminal box is ready to be connected.
  • Speed-controllable.
  • Thermal overload protection (temperature sensor in motor winding) as a standard feature.
  • The overload protection automatically switches the fan off in the event of overheating.
  • Robust motor with ball bearings, maintenance-free.
  • IP X4 degree of protection when installed in ventilation ducts with at least 1 m of duct on the inlet and outlet sides.

Installation information

  • Can be fitted in any position.
  • Use optional ELR flexible cuffs to prevent transfer of vibrations to the duct system.

Electrical connection

  • Externally fitted terminal box with cable guide bushes.

Safety information

  • The fan may be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN ISO 13857 for fans with free inlet or outlet. To do this, fit an optional SGR protective grille.

Table of contents

Wiring diagram

ERR 20/1 - Wiring diagram

ERH... electric air heater with LW 9 air flow monitor and ST speed controller

K1 - heating release (US16T)

ERR .. / 1 - centrifugal fan

LW 9 - air flow monitor

ETL 16 P - electronic temperature controller

DTL 16 P - electronic temperature controller

FL 30P channel sensor

ST.. STU.., STS.. speed controller

ERH - electric air heater

F1 - temperature limiter

F2 - safety temperature limiter

N - night reduction

  1. Only with DTL 16 P


Centrifugal fan


Centrifugal fan with humidity switch HY 230/HY 230 I


Centrifugal fan with ST/STU/STS speed controller


Centrifugal fan with TRE 5-step transformer


Duct fan with ERH 16-2 R electric air heater

S1 - system on

US16 - all-pole isolating switch (contactor)

ERR... centrifugal duct fan

ERH...R electrical air heater: ERH16-2R

B=Int/ext bridge must be closed

C=Do not change potentiometer setting

D=Setpoint potentiometer for MIN limitation

E=Setpoint potentiometer for MAX limitation

F=Bridge for MAX limitation, bridge must be closed!

G=If bridge is closed, MIN limitation is also active

FR30P - ext. setpoint controller (0-30°C) with room sensor

FL30P - ext. channel sensor for MIN, MAX limitation

LW9 - air flow monitor (in position N)

Installation of LW9 sensor on incoming side of air heater

0-30°C setpoint setting and recording of room temperature with FR30P

0-60°C min/max limitation in supply air channel with FL60P



Duct fan with electric air heater DRH 16-5R and DRH 20-6R

S1 - system on

US16 - all-pole isolating switch (contactor)

ERR... centrifugal duct fan

DRH...R electric air heater: DRH16-2R or DRH20-6R

B=Int/ext bridge must be closed

C=Do not change potentiometer setting

D=Setpoint potentiometer for MIN limitation

E=Setpoint potentiometer for MAX limitation

F=Bridge for MAX limitation, bridge must be closed!

G=If bridge is closed, MIN limitation is also active

FR30P - ext. setpoint controller (0-30°C) with room sensor

FL30P - ext. channel sensor for MIN, MAX limitation

LW9 - air flow monitor (in position N)

Installation of LW9 sensor on incoming side of air heater

0-30°C setpoint setting and recording of room temperature with FR30P

0-60°C min/max limitation in supply air channel with FL60P



Duct fan with DRH 25-9R, DRH 31-12R, DRH 35-12R and DRH 40-12R electric air heaters

S1 - system on

S - sensor

US16 - all-pole isolating switch (contactor)

ERR... centrifugal duct fan

DRH...R electric air heater: DRH 25-9R, DRH 31-12R, DRH 35-12R, DRH 40-12R

B=Int/ext bridge must be closed

C=Do not change potentiometer setting

D=Setpoint potentiometer for MIN limitation

E=Setpoint potentiometer for MAX limitation

F=Bridge for MAX limitation, bridge must be closed!

G=If bridge is closed, MIN limitation is also active

FR30P - ext. setpoint controller (0-30°C) with room sensor

FL60P - ext. channel sensor for MIN, MAX limitation

LW9 - air flow monitor (in position N)

Installation of LW9 sensor on incoming side of air heater

0-30°C setpoint setting and recording of room temperature with FR30P

0-60°C min/max limitation in supply air channel with FL60P



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings