Axial built-in wall fan

EZF 25/4 E

Article number: 0085.0486
Manufacturer: MAICO
Axial built-in wall fan for flush-mounted installation, DN250, single-phase AC
Application examples: Changing room, Foreman's office, Restaurant, Garage, Fitness room
Product data sheet
EZF 25/4 E IM0009978.PNG Axial built-in wall fan for flush-mounted installation, DN250, single-phase AC

Characteristic curve

EZF 25/4 E - Characteristic curve

Dimensioned drawing

EZF 25/4 E - Dimensioned drawing [mm]

  1. Protective grille on intake side
  2. Air flow direction with air drawn across the motor

Technical data

EZF 25/4 E - Technical data

Article EZF 25/4 E
Model Wall sleeve
Air flow volume 800 m³/h
Rotating speed 1.280 1/min
Impeller type axial
Speed controllable
Reversing capacity
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Nominal output 40 W
Power consumption 50 W
Inom 0,28 A
Imax 0,3 A
Degree of protection IP 54
Insulation class E
Mains cable 3 x 1,5 mm²
Installation site Wall / Ceiling
Type of installation Recessed-mounted
Installation position horizontal / vertical
Material Sheet steel, galvanised
Colour Silver
Weight 3,85 kg
Weight including packaging 4,68 kg
Nominal size 250 mm
Width 320 mm
Height 320 mm
Depth 240 mm
Width with packaging 330 mm
Height with packaging 435 mm
Depth with packaging 420 mm
Airstream temperature at nominal current -20 °C up to 50 °C
Airstream temperature at IMax -20 °C up to 50 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799854869
Article number 0085.0486

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA7, S5 (dB(A))

25

47

50

54

53

53

46

34

59

LWA7= housing and free inlet sound power level in dB.

Accessories

EZF 25/4 E - Accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
Shutter AS 25 0151.0331 on request
  • On the notes
Shutter, manual RS 25 0151.0339 on request
  • On the notes
Servomotor MS 2 0093.0403 on request
  • On the notes
External grille MLA 25 0151.0112 on request
  • On the notes
External grille MLZ 25 0151.0102 on request
  • On the notes
Extension sleeve VH 25 0055.0031 on request
  • On the notes
Internal grille IG 25 0059.0172 on request
  • On the notes
Dark room attachment ZDK 25 0093.0350 on request
  • On the notes
Air filter ZFF 30 0149.0003 on request
  • On the notes
Main switch, service switch HS 3 0157.0736 on request
  • On the notes
Rotary switch DS 10 0157.0410 on request
  • On the notes
Contactor US 16 T 0157.0769 on request
  • On the notes
Cellar dehumidification control AKE 0157.0129 on request
  • On the notes
Speed controller STX 1,5 0157.1561 on request
  • On the notes
Speed controller, distribution board STSX 2,5 0157.1564 on request
  • On the notes
5-step transformer TRE 0,4-2 0157.0156 on request
  • On the notes
5-step transformer, control cabinet TRE 1,6 S-2 0157.0162 on request
  • On the notes
5-step switch for TRE...S -2/ TR...S-2 5-step transformers ESS 20 0157.0749 on request
  • On the notes
Thermostat THR 10-1 0157.0191 on request
  • On the notes
Thermostat TH 10 0157.0764 on request
  • On the notes
Thermostat TH 16 0157.0748 on request
  • On the notes
Temperature control system EAT 6 TG Discontinued product 0157.0755 on request
  • On the notes
Hygrostat HY 230 0157.0126 on request
  • On the notes
Hygrostat HY 230 I 0157.0127 on request
  • On the notes
Air quality controller EAQ 10/1 Discontinued product 0157.0777 on request
  • On the notes
Cellar dehumidification control AKE/1 New development 0157.1683 on request
  • On the notes
Thermostat THR 10 No longer available for delivery 0157.0774 on request
  • On the notes
Thermostat THD 10 No longer available for delivery 0157.0775 on request
  • On the notes
Temperature control system EAT 6 G/1 No longer available for delivery 0157.0808 on request
  • On the notes
Speed controller ST 1 No longer available for delivery 0157.0810 on request
  • On the notes
Speed controller STU 1 No longer available for delivery 0157.0814 on request
  • On the notes
Speed controller, distribution board STS 2,5 No longer available for delivery 0157.0255 on request
  • On the notes
Temperature control system, power module EALT 6 No longer available for delivery 0157.0756 on request
  • On the notes
Hygrostat HY 10 AP No longer available for delivery 0157.0358 on request
  • On the notes
Hygrostat HY 10 UP No longer available for delivery 0157.0357 on request
  • On the notes

Product description

Productdescription

EZF 25/4 E

short description

Axial built-in wall fan for flush-mounted installation, DN250, single-phase AC

Product description

Single-phase AC model

  • Axial built-in wall fan for flush-mounted installation, in single-phase AC version

Brief description

  • For flush mounting.
  • Can be fitted in any position.
  • Wall sleeve made of galvanised sheet steel.
  • 8-blade impellers made of glass fibre reinforced polyamide
  • Protective grille made of plastic on the intake side, pearl white, protection against accidental contact in accordance with DIN EN 13857.
  • Thermal overload protection as a standard feature.
  • Vibration-free running due to dynamically balanced impeller and motor (shaft-rotor), according to quality class 6.3, DIN ISO 1940, part 1.
  • High efficiency on the ventilation side, low operating noise.
  • Increased durability due to high-quality materials such as quiet ball bearings.
  • Fans are maintenance-free.

Air flow direction

  • The air flow direction is marked.
  • Standard exhaust air mode, air flow direction with air drawn across motor.

AC motor

  • EZF type series
  • Asynchronous motor.
  • Rated voltage 230 V, 50 Hz.
  • IP 55 degree of protection. Exception EZF... D, EZF ... E IP 54.
  • Fans “... B”: Capacitor motors with operating capacitor on the protective grille or on the wall sleeve.
  • Fans “... D”: Capacitor motors with operating capacitor in terminal box.
  • Fans “... E”: Shaded-pole motors, non-reversible.
  • Thermal overload protection as a standard feature.
  • Speed-controllable. Units can be steplessly controlled with optional speed controllers or they can be steplessly switched with an optional 5-step transformer.
  • Reversible. Exception: For fans with shaded-pole motor (“... E”).
  • Reversing mode: The volumetric flow is reduced by approx. 35 % with abnormal air flow direction.
  • Not suitable for ventilating steam-saturated air.

Electrical connection

  • On terminal block in end cover of the motor.

Safety information

  • The fan can be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN 13857 for fans with a free inlet.

Special versions

  • The following special versions are available on request, at an extra cost:
    • Special voltages and frequencies.
    • Single-phase motors with thermal contacts or PTC thermistor, potential-free terminal connection.
    • Impellers made of aluminium.
  • Information on operation at temperatures occasionally below -20°C available upon request.
  • If operating with frequency converters, the factory must be consulted.
  • Feasibility must be checked in each case.

Table of contents

Wiring diagram

EZF 25/4 E - Wiring diagram



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings