Axial duct fan

EZR 20/2 B

Article number: 0086.0000
Manufacturer: MAICO
Axial duct fan, DN 200, alternating current
Application examples: Machine extraction unit, Showroom, Foreman's office, Workshop, Production site
Product data sheet
EZR 20/2 B IM0009987.PNG Axial duct fan, DN 200, alternating current

Characteristic curve

EZR 20/2 B - Characteristic curve

Dimensioned drawing

EZR 20/2 B - Dimensioned drawing [mm]

Number of flange holes: 6

Technical data

EZR 20/2 B - Technical data

Article EZR 20/2 B
Air flow volume 1.100 m³/h
Rotating speed 2.850 1/min
Impeller type axial
Speed controllable
Reversing capacity
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Nominal output 65 W
Inom 0,3 A
Imax 0,51 A
Degree of protection IP 55
Insulation class B
Pole-changeable
Installation position horizontal / vertical
Material Sheet steel, galvanised
Colour Silver
Weight 5,93 kg
Weight including packaging 6,52 kg
Nominal size 200 mm
Width 254 mm
Height 317 mm
Depth 240 mm
Width with packaging 345 mm
Height with packaging 340 mm
Depth with packaging 265 mm
Airstream temperature at nominal current -20 °C up to 60 °C
Airstream temperature at IMax -20 °C up to 60 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799860006
Article number 0086.0000

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, S1 (dB(A))

14

19

28

23

23

18

21

26

32

LWA2, S2 (dB(A))

18

36

46

45

44

43

39

39

52

LWA2, S3 (dB(A))

23

37

53

52

52

52

48

44

59

LWA2, S4 (dB(A))

26

38

54

54

54

54

50

46

61

LWA2, S5 (dB(A))

27

39

54

55

55

55

51

47

62

LWA5, S1 (dB(A))

21

15

29

34

26

18

21

23

36

LWA5, S2 (dB(A))

23

35

54

58

56

58

55

43

63

LWA5, S3 (dB(A))

35

40

61

64

63

65

63

53

71

LWA5, S4 (dB(A))

40

40

58

71

66

67

64

55

74

LWA5, S5 (dB(A))

37

40

57

74

67

68

65

56

76

LWA6, S1 (dB(A))

14

21

26

32

30

25

24

24

36

LWA6, S2 (dB(A))

25

37

49

60

64

62

58

47

68

LWA6, S3 (dB(A))

32

41

54

68

70

69

65

57

74

LWA6, S4 (dB(A))

36

41

51

68

72

71

67

60

76

LWA6, S5 (dB(A))

34

42

52

70

73

72

68

60

77

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

Accessories

EZR 20/2 B - Accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
Shutter AS 20 0151.0330 on request
  • On the notes
Shutter, manual RS 20 0151.0338 on request
  • On the notes
Servomotor MS 2 0093.0403 on request
  • On the notes
Internal grille IG 20 0059.0171 on request
  • On the notes
Protective grille, metal SG 20 0150.0114 on request
  • On the notes
Protective grille, synthetic material SGK 20 0059.0161 on request
  • On the notes
Flexible coupling ELA 20 0092.0265 on request
  • On the notes
Flexible cuff EL 20 0092.0154 on request
  • On the notes
Counter socket GS 20 0055.0168 on request
  • On the notes
Suction nozzle AD 20 0180.0628 on request
  • On the notes
Mounting foot FU 20 0036.0069 on request
  • On the notes
Vibration damper GP 10 0092.0151 on request
  • On the notes
Main switch, service switch HS 3 0157.0736 on request
  • On the notes
Rotary switch DS 10 0157.0410 on request
  • On the notes
Reversing switch W 1 0157.0101 on request
  • On the notes
Reversing switch WU 1 Discontinued product 0157.0102 on request
  • On the notes
Reversing switch FS 7 0016.0107 on request
  • On the notes
Contactor US 16 T 0157.0769 on request
  • On the notes
Speed controller STX 1,5 0157.1561 on request
  • On the notes
Speed controller, distribution board STSX 2,5 0157.1564 on request
  • On the notes
Reversing switch UWK 1 Discontinued product 0157.0817 on request
  • On the notes
5-step transformer TRE 0,6-2 0157.0157 on request
  • On the notes
5-step transformer, control cabinet TRE 1,6 S-2 0157.0162 on request
  • On the notes
5-step switch for TRE...S -2/ TR...S-2 5-step transformers ESS 20 0157.0749 on request
  • On the notes
Thermostat THR 10-1 0157.0191 on request
  • On the notes
Thermostat TH 10 0157.0764 on request
  • On the notes
Thermostat TH 16 0157.0748 on request
  • On the notes
Temperature control system EAT 6 TG Discontinued product 0157.0755 on request
  • On the notes
Air flow monitor LW 9 0157.0779 on request
  • On the notes
Hygrostat HY 230 0157.0126 on request
  • On the notes
Hygrostat HY 230 I 0157.0127 on request
  • On the notes
Air quality controller EAQ 10/1 Discontinued product 0157.0777 on request
  • On the notes
Speed controller, reversing switch STW 1 No longer available for delivery 0157.0813 on request
  • On the notes
Thermostat THR 10 No longer available for delivery 0157.0774 on request
  • On the notes
Thermostat THD 10 No longer available for delivery 0157.0775 on request
  • On the notes
Temperature control system EAT 6 G/1 No longer available for delivery 0157.0808 on request
  • On the notes
Mounting and sealing material BD 20 No longer available for delivery 0092.0132 on request
  • On the notes
Speed controller ST 1 No longer available for delivery 0157.0810 on request
  • On the notes
Speed controller STU 1 No longer available for delivery 0157.0814 on request
  • On the notes
Speed controller, distribution board STS 2,5 No longer available for delivery 0157.0255 on request
  • On the notes
Temperature control system, power module EALT 6 No longer available for delivery 0157.0756 on request
  • On the notes
Hygrostat HY 10 AP No longer available for delivery 0157.0358 on request
  • On the notes
Hygrostat HY 10 UP No longer available for delivery 0157.0357 on request
  • On the notes

Product description

Productdescription

EZR 20/2 B

short description

Axial duct fan, DN 200, alternating current

Product description

AC model

  • Axial duct fan, in single-phase AC version.

Brief description

  • Duct sleeve made of galvanised sheet steel, with flanges on both sides.
  • 8-blade impellers made of glass fibre reinforced polyamide
  • Flange holes in accordance with DIN EN 12220:1998.
  • DZR 56/6 B and DZR 56/4 B: Flange holes in accordance with DIN EN 12220: 1998.
  • To avoid transmission of vibrations to the duct system: Use flexible couplings, feet and vibration dampers.
  • Thermal overload protection as a standard feature.
  • Fans meet the requirements of the European Ecodesign Directive (EC) No.327/2011 Directive 2009/125/EC.
  • Vibration-free running due to dynamically balanced impeller and motor (shaft-rotor), according to quality class 6.3, DIN ISO 1940, part 1.
  • High efficiency on the ventilation side, low operating noise.
  • Increased durability due to high-quality materials such as quiet ball bearings.
  • Fans are maintenance-free.
  • Can be fitted in any position.

Air flow direction

  • The air flow direction is marked.
  • Standard exhaust air mode, air flow direction with air drawn across motor.

AC motor

  • EZR type series.
  • Asynchronous motor.
  • Not suitable for ventilating steam-saturated air.
  • Rated voltage 230 V, 50 Hz.
  • High degree of protection IP 55. Exception EZR... D IP 54.
  • Speed-controllable.
  • Units can be steplessly controlled with optional speed controllers or they can be steplessly switched with an optional 5-step transformer.
  • Reversible.
  • Reversing mode: The volumetric flow is reduced by approx. 35 % with abnormal air flow direction.
  • Capacitor motors with operating capacitor ready for use in terminal box.
  • Thermal overload protection as a standard feature.
  • Potential-free terminal connections, which must be connected to, e.g., an MVE 10-1 full motor protection switch (not suitable for EZR 25/4 D, EZR 30/6 B and EZR 35/6 B) or the control circuit of a contactor.

Electrical connection

  • Terminal box with cable sleeves fitted on the outside.

Safety information

  • The fan may be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN ISO 13857, e.g., with Maico SG protective grille.

Special versions

  • The following special versions are available on request, at an extra cost:
    • Special voltages and frequencies.
    • PTC thermistor, potential-free terminal connection.
    • Condensation drainage holes.
    • Fans with enhanced anti-corrosion protection.
    • Impellers made of aluminium.
  • Information on operation at temperatures occasionally below -20°C available upon request.
  • If operating with frequency converters, the factory must be consulted.
  • Feasibility must be checked in each case.

Table of contents

Wiring diagram

EZR 20/2 B - Wiring diagram

With TRE... 5-step transformer.


With MVE 10-1 motor protection switch

MVE 10-1 not for EZR 25/4 D, EZR 30/6 B and EZR 35/6 B



With STX / STSX speed controller and MVE 10-1 motor protection switch

MVE 10-1 not for EZR 25/4 D, EZR 30/6 B and EZR 35/6 B



With TRE... 5-step transformer and MVE 10-1 motor protection switch

MVE 10-1 not for EZR 25/4 D, EZR 30/6 B and EZR 35/6 B



With contactor circuit (self-switching)


With STX / STSX speed controller


Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings