Centrifugal blower

GRM 12/2 D Ex

Article number: 0073.0387
Manufacturer: MAICO
Centrifugal blower, size 120, three-phase AC, for use in potentially explosive atmospheres, medium: gas
Application examples: explosion-proof industrial applications
Product data sheet
GRM 12/2 D Ex IM0020476.PNG Centrifugal blower, size 120, three-phase AC, for use in potentially explosive atmospheres, medium: gas
GRM 12/2 D Ex IM0017898.PNG Centrifugal blower, size 120, three-phase AC, for use in potentially explosive atmospheres, medium: gas

Characteristic curve

GRM 12/2 D Ex - Characteristic curve

Dimensioned drawing

GRM 12/2 D Ex - Dimensioned drawing [mm]

GRM 12/2 D Ex - Dimensioned drawing Housing orientation [mm]

  1. RD Right-hand version
  2. LG Left-hand version

This size cannot be ordered in the versions 45°, 135°, 315°

The standard orientation is always LG 270°

Technical data

GRM 12/2 D Ex - Technical data

Article GRM 12/2 D Ex
Air flow volume 900 m³/h
Rotating speed 2.880 1/min
Impeller type radial
Speed controllable
Reversing capacity
Type of voltage Three-phase AC
Rated voltage 400 V
Frequency 50 Hz
Nominal output 250 W
Inom 0,62 A
Degree of protection IP 55
Insulation class F
Pole-changeable
Installation site Duct connection
Installation position Horizontal
Material Sheet steel, galvanised
Housing material Steel
Colour grey
Weight 10 kg
Weight including packaging 10,6 kg
Size 120 mm
Width 300 mm
Height 272 mm
Depth 246 mm
Width with packaging 400 mm
Height with packaging 335 mm
Depth with packaging 290 mm
EX designation in accordance with the ATEX Directive Ex II 2 G
EX designation in accordance with standard Ex db IIB+H2 T4 Gb X / Ex h IIB+H2 T4 Gb X
Ta ambient temperature -20 °C ≤ Ta ≤ +40 °C
Operating mode S1
PTC DIN 44082 M 100
Temperature class T4
Packing unit 1 piece
Range C
GTIN (EAN) 4012799733874
Article number 0073.0387

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA5, S5 (dB(A))

44

54

68

73

69

74

69

65

78

LWA5= free inlet sound power level in dB.

Accessories

GRM 12/2 D Ex - Accessories

Specific accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
Air outlet grille SGAI 12 0073.0289 on request
  • On the notes
Inlet protective grille SGEI 12 0073.0285 on request
  • On the notes

Product description

Productdescription

GRM 12/2 D Ex

short description

Centrifugal blower, size 120, three-phase AC, for use in potentially explosive atmospheres, medium: gas

Product description

Features

  • Centrifugal blower made of metal for applications in areas subject to explosion hazards.
  • Explosion protection tested in accordance with Directive 2014/34/EU.
  • Qualified for all gases and vapours of Ex group IIA and IIB and also for hydrogen.
  • Ex II 2 G Ex db IIB+H2 T4 Gb X / Ex II 2 G Ex h IIB+H2 T4 Gb X.
  • For usage temperatures of -20°C ≤ Ta ≤ +40°C.
  • MAICO Ex fans fulfil the safety requirements of European Directive 2014/34/EU for units and protective systems in potentially explosive atmospheres.
  • For zone 1 and 2.
  • Types of ignition protection: “d” – pressure-proof housing and “c” – constructional safety.
  • Powerful fans for industrial applications.
  • For simple and direct mounting on a duct system.
  • The motor is outside the air flow.
  • Sheet steel housing.
  • Standard orientation for LG 270° housing.
  • Suitable for temperature ranges from -20 °C to +40 °C.
  • The intake socket, made of coated sheet steel, is included in the scope of delivery.
  • Centrifugal impellers with forward curved blades made of galvanised sheet steel.

Three-phase AC motor

  • Three-phase AC motor.
  • IP 55 degree of protection.
  • IE3 motor.
  • S1 operating mode (continuous operation).
  • Temperature class T4.
  • Speed-controllable with frequency converter.
  • Permissible frequency range for speed control with frequency converter 20-50 Hz.
  • The temperature in the fan motor is monitored by PTC thermistors. The PTC thermistors must be connected to a triggering system (safety device according to Directive 2014/34/EU), that separates the fan permanently from the power if the temperature gets too hot.

Electrical connection

  • Connection in the terminal box on the motor.
  • Cable screw connection, in Ex d version, included in the scope of delivery.

Special versions

  • The following special versions are available on request, at an extra cost:
    • Deviating housing orientation.

Table of contents

Wiring diagram

GRM 12/2 D Ex - Wiring diagram



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings