WS 170 KL - Characteristic curve
I - Interval / vacation operation for humidity protection
- Reduced ventilation
- Nominal ventilation
- Intensive / Party operation
- Recommended setting range
Characteristic curve
Dimensioned drawing
Technical data
Accessories
Product type | Name | Art. No. | Price*(EUR) | Action |
---|---|---|---|---|
Room air control | RLS G1 WS | 0157.1593 | on request | |
Plug connectors for ducts | SVR 125 | 0055.0183 | on request | |
45° elbow, drawn | B45-125 | 0055.0326 | on request | |
90° elbow, drawn | B90-125 | 0055.0312 | on request | |
Air filter, replacement | WSF 170 | 0093.0271 | on request | |
Air filter, replacement | WSF-AKF 170 | 0093.0272 | on request | |
Air filter, replacement | WSG 170 | 0093.0270 | on request | |
Push-in frame for air filter | WSG-ES 170 | 0093.0269 | on request | |
Room air control | RLS 1 WR | 0157.0809 | on request | |
Room air control | RLS T1 WS Discontinued product | 0157.0835 | on request | |
Room air control | RLS T2 WS | 0157.1656 | on request | |
harmful gas sensor | SGS | 0093.1323 | on request | |
EnOcean plug-in module | E-SM | 0092.0556 | on request | |
KNX plug-in module | K-SM | 0092.0557 | on request | |
Additional circuit board | ZP 1 | 0092.0554 | on request | |
Additional circuit board | ZP 2 | 0092.0555 | on request |
Product description
Productdescription
Wiring diagram
A - WS 170 / RB 170 ventilation unit
A1 - Electronic slide-in module
A2 - Controlled domestic ventilation unit control
B1- RLS 1 WR / RB-ZF4 single control unit
B2-B5 - Parallel connection max. 5 single control units
BTS - RLS T1 WS touchscreen control unit
W1 - 230 V AC connecting cable
W2 - Screened control cable for single control unit (provided by customer), e.g. LIYY 6 x 0.34 mm²
W2' - RLS T1 WS screened control cable (provided by customer), e.g. LIYY 4 x 0.34 mm²
W5 - Connecting cable for PTC heat register
W7 - Connecting cable for bypass motor
S1 - Unit switch
S2 - Door contact switch
M1 - Exhaust air/outgoing air fan
M2 - Outside air/supply air fan
T-LET - Temperature sensor for air inlet for outside air
T-FOL - Temperature sensor for outgoing air
T-ZUL - Temperature sensor for supply air
S-ABL - Combination sensor for exhaust air
Further connection options
W2' - Connecting cable for RLS T1 WS or Modbus touchscreen control unit, e.g. LIYY 4 x 0.34 mm²
W3 - Connecting cable (provided by customer) for external safety device with potential-free contact 12 V/2 A
W4 - Connecting cable for door contact switch
W8 - Connecting cable (provided by customer) for external sensor 1
W9 - Connecting cable (provided by customer) for external sensor 2
X01 - Slot for optional communication plug-in module EnOcean/KNX
ZP1 - 230 VAC connecting terminals for switching the additional circuit boards
USB - USB service interface Ethernet network interface (LAN)
A - WS 170 electronic slide-in module
A2 - Control circuit board: jumper 8 bridged (= factory setting)
B1 - 1. RLS 1 WR room air control
B2 - 2. RLS 1 WR room air control
W1 - 230 V AC connecting cable
W2' - Control cable for room air control
V - Distributor (supplied by the customer)
You can connect up to 5 RLS 1 WR room air controls to the ventilation unit. If several room air controls are used, no CO2 sensor may be connected.
RLS 1 WR room air control can also be connected to RLS D1 WR room air control.
No need for distributor "V" if only one RLS 1 WR room air control is connected.
A - WS 170 electronic slide-in module
A2 - Control circuit board: jumper 8 bridged (= factory setting)
B1 - 1. RLS 1 WR room air control
B2 - 2. RLS 1 WR room air control
W1 - 230 V AC connecting cable
W2' - Control cable for room air control
V - Distributor (supplied by the customer)
You can connect up to 5 RLS 1 WR room air controls to the ventilation unit. If several room air controls are used, no CO2 sensor may be connected.
RLS 1 WR room air control can also be connected to RLS D1 WR room air control.
No need for distributor "V" if only one RLS 1 WR room air control is connected.
A - Ventilation unit
A1 - Electronic slide-in module
A2 - Controlled domestic ventilation unit control
CO2 - CO2-sensor ( accessories)
VOC - Air quality controller ( accessories)
r.h. - Humidity sensor ( accessories)
T-S - Intermittent ventilation button / external potential-free contact
W8 - Connecting cable (provided by customer) for external VOC sensor, e.g. LIYY 3 x 0.5 mm²
W8' - Connecting cable (provided by customer) for external r.h. sensor 1, e.g. LIYY 3 x 0.5 mm²
W8'' - Connecting cable (provided by customer) external pushbutton / potential-free contact (function – intermittent ventilation/sensor type = digital), e.g. LIYY 2 x 0.5 mm²
W9 - Connecting cable (provided by customer) external CO2 sensor 2, e.g. LIYY 3 x 0.5 mm² W10 - Connecting cable (provided by customer) external sensor 3, e.g. LIYY 3 x 0.5 mm²
W11 - Connecting cable (provided by customer) for external sensor 4, e.g. LIYY 3 x 0.5 mm²
The control’s sensor inputs can be freely parametrised.
The inputs are not defined for a particular sensor type.
When commissioning a sensor, the sensor input on the control must be activated and the sensor type specified Commissioning and maintenance instructions.
If the RLS 1 WR is deactivated (parameters – single control unit
inactive) on the controller, a connection of up to four sensors is possible.
The power supply to sensors 3 + 4 can be ensured via terminals LD1, LD2, LD3 (all 12 VDC) or with double assignment, via the 24 VDC supply of sensor connections.
Downloads / Videos
Predecessor - successor
On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.
Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.
Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.
These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.