DAR-Ex - DN 800

Three-phase AC fans, DN 800, air volume 10989 m³/h to 31500 m³/h (medium: gas)

DAR-Ex - DN 800 IM0021313.PNG Three-phase AC fans, DN 800, air volume 10989 m³/h to 31500 m³/h (medium: gas)

Below you can see a direct comparison of the products you have selected. Differences between the products are highlighted in blue.

ArticleDAR 80/8-1 ExDAR 80/8-2 ExDAR 80/8-3 ExDAR 80/6-1 ExDAR 80/6-2 ExDAR 80/6-3 ExDAR 80/4-1 ExDAR 80/4-2 ExDAR 80/4-3 Ex
Product detailsProduct detailsProduct detailsProduct detailsProduct detailsProduct detailsProduct detailsProduct detailsProduct details
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
Product type Axial duct fan Axial duct fan Axial duct fan Axial duct fan Axial duct fan Axial duct fan Axial duct fan Axial duct fan Axial duct fan
Article number: 0073.0360 0073.0361 0073.0362 0073.0357 0073.0358 0073.0359 0073.0354 0073.0355 0073.0356
Model

Motor variant 1

Motor variant 2

Motor variant 3

Motor variant 1

Motor variant 2

Motor variant 3

Motor variant 1

Motor variant 2

Motor variant 3

Air flow volume

14.751 m³/h

12.885 m³/h

10.989 m³/h

19.951 m³/h

18.374 m³/h

14.000 m³/h

31.500 m³/h

26.140 m³/h

23.627 m³/h

Rotating speed

720 1/min

720 1/min

720 1/min

960 1/min

960 1/min

960 1/min

1.440 1/min

1.440 1/min

1.440 1/min

Impeller type

axial

axial

axial

axial

axial

axial

axial

axial

axial

Speed controllable

Rated voltage

400 V

400 V

400 V

400 V

400 V

400 V

400 V

400 V

400 V

Frequency

50 Hz

50 Hz

50 Hz

50 Hz

50 Hz

50 Hz

50 Hz

50 Hz

50 Hz

Nominal output

550 W

550 W

370 W

1.500 W

1.100 W

750 W

5.500 W

4.000 W

3.000 W

Inom

1,85 A

1,85 A

1,3 A

3,8 A

2,7 A

2,7 A

11,94 A

8,8 A

6,55 A

Imax

1,9 A

1,9 A

1,3 A

3,9 A

3,2 A

2,2 A

11,4 A

8,7 A

6,6 A

Degree of protection

IP 55

IP 55

IP 55

IP 55

IP 55

IP 55

IP 55

IP 55

IP 55

Insulation class

F

F

F

F

F

F

F

F

F

Pole-changeable

-

-

-

-

-

-

-

-

-

Installation site

Duct connection

Duct connection

Duct connection

Duct connection

Duct connection

Duct connection

Duct connection

Duct connection

Duct connection

Installation position

vertical / horizontal

vertical / horizontal

vertical / horizontal

vertical / horizontal

vertical / horizontal

vertical / horizontal

vertical / horizontal

vertical / horizontal

vertical / horizontal

Housing material

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Colour

grey

grey

grey

grey

grey

grey

grey

grey

grey

Weight

90 kg

90 kg

90 kg

90 kg

90 kg

90 kg

90 kg

90 kg

90 kg

Weight including packaging

135 kg

135 kg

135 kg

135 kg

135 kg

135 kg

135 kg

135 kg

135 kg

Nominal size

800 mm

800 mm

800 mm

800 mm

800 mm

800 mm

800 mm

800 mm

800 mm

Width

910 mm

910 mm

910 mm

910 mm

910 mm

910 mm

910 mm

910 mm

910 mm

Height

590 mm

590 mm

590 mm

590 mm

590 mm

590 mm

590 mm

590 mm

590 mm

Depth

910 mm

910 mm

910 mm

910 mm

910 mm

910 mm

910 mm

910 mm

910 mm

Width with packaging

1.140 mm

1.140 mm

1.140 mm

1.140 mm

1.140 mm

1.140 mm

1.140 mm

1.140 mm

1.140 mm

Height with packaging

730 mm

730 mm

730 mm

730 mm

730 mm

730 mm

730 mm

730 mm

730 mm

Depth with packaging

1.140 mm

1.140 mm

1.140 mm

1.140 mm

1.140 mm

1.140 mm

1.140 mm

1.140 mm

1.140 mm

EX designation in accordance with the ATEX Directive

Ex II 2 G

Ex II 2 G

Ex II 2 G

Ex II 2 G

Ex II 2 G

Ex II 2 G

Ex II 2 G

Ex II 2 G

Ex II 2 G

EX designation in accordance with standard

Ex db IIB+H2 T4 Gb X / Ex h IIB+H2 T4 Gb X

Ex db IIB+H2 T4 Gb X / Ex h IIB+H2 T4 Gb X

Ex db IIB+H2 T4 Gb X / Ex h IIB+H2 T4 Gb X

Ex db IIB+H2 T4 Gb X / Ex h IIB+H2 T4 Gb X

Ex db IIB+H2 T4 Gb X / Ex h IIB+H2 T4 Gb X

Ex db IIB+H2 T4 Gb X / Ex h IIB+H2 T4 Gb X

Ex db IIB+H2 T4 Gb X / Ex h IIB+H2 T4 Gb X

Ex db IIB+H2 T4 Gb X / Ex h IIB+H2 T4 Gb X

Ex db IIB+H2 T4 Gb X / Ex h IIB+H2 T4 Gb X

Ta ambient temperature

-20 °C ≤ Ta ≤ +40 °C

-20 °C ≤ Ta ≤ +40 °C

-20 °C ≤ Ta ≤ +40 °C

-20 °C ≤ Ta ≤ +40 °C

-20 °C ≤ Ta ≤ +40 °C

-20 °C ≤ Ta ≤ +40 °C

-20 °C ≤ Ta ≤ +40 °C

-20 °C ≤ Ta ≤ +40 °C

-20 °C ≤ Ta ≤ +40 °C

Operating mode

S1

S1

S1

S1

S1

S1

S1

S1

S1

PTC DIN 44082

M 100

M 100

M 100

M 100

M 100

M 100

M 100

M 100

M 100

Temperature class

T4

T4

T4

T4

T4

T4

T4

T4

T4

Packing unit

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

Range

C

C

C

C

C

C

C

C

C

GTIN (EAN)

4012799733607

4012799733614

4012799733621

4012799733577

4012799733584

4012799733591

4012799733546

4012799733553

4012799733560

* Blue markings show the differences between the products.

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings