DN 300

Three-phase AC fans, nominal size 300, air volume 1250 m³/h to 3800 m³/h (medium: gas)

DN 300 IM0013760.PNG Three-phase AC fans, nominal size 300, air volume 1250 m³/h to 3800 m³/h (medium: gas)

Below you can see a direct comparison of the products you have selected. Differences between the products are highlighted in blue.

ArticleDZQ 30/6 B Ex eDZS 30/6 B Ex eDZQ 30/4 B Ex eDZS 30/4 B Ex eDZQ 30/2 B Ex eDZS 30/2 B Ex e
Product detailsProduct detailsProduct detailsProduct detailsProduct detailsProduct details
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
  • On the notes
Product type Axial wall fan Axial wall fan Axial wall fan Axial wall fan Axial wall fan Axial wall fan
Article number: 0083.0174 0094.0120 0083.0175 0094.0121 0083.0176 0094.0122
Model

Square wall plate

Steel wall ring

Square wall plate

Steel wall ring

Square wall plate

Steel wall ring

Air flow volume

1.100 m³/h

1.100 m³/h

1.730 m³/h

1.730 m³/h

3.380 m³/h

3.380 m³/h

Rotating speed

985 1/min

985 1/min

1.475 1/min

1.475 1/min

2.910 1/min

2.910 1/min

Impeller type

axial

axial

axial

axial

axial

axial

Speed controllable

Reversing capacity

Type of voltage

Three-phase AC

Three-phase AC

Three-phase AC

Three-phase AC

Three-phase AC

Three-phase AC

Rated voltage

400 V

400 V

400 V

400 V

400 V

400 V

Frequency

50 Hz

50 Hz

50 Hz

50 Hz

50 Hz

50 Hz

Nominal output

25 W

25 W

95 W

95 W

240 W

240 W

cosφ

0,27

0,27

0,28

0,28

0,73

0,73

Inom

0,12 A

0,12 A

0,48 A

0,48 A

0,46 A

0,46 A

Imax at UNominal

0,13 A

0,13 A

0,49 A

0,49 A

0,85 A

0,85 A

Degree of protection

IP 64

IP 64

IP 64

IP 64

IP 64

IP 64

Insulation class

F

F

F

F

F

F

Installation site

Wall / Ceiling

Wall / Ceiling

Wall / Ceiling

Wall / Ceiling

Wall / Ceiling

Wall / Ceiling

Type of installation

Surface-mounted

Surface-mounted

Surface-mounted

Surface-mounted

Surface-mounted

Surface-mounted

Installation position

vertical / horizontal

vertical / horizontal

vertical / horizontal

vertical / horizontal

vertical / horizontal

vertical / horizontal

Material

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Housing material

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Colour

galvanised

galvanised

galvanised

galvanised

galvanised

galvanised

Weight

12,02 kg

7,9 kg

9,41 kg

7,42 kg

12,47 kg

10,5 kg

Weight including packaging

13,62 kg

8,3 kg

11,08 kg

9,24 kg

14,09 kg

12,33 kg

Nominal size

300 mm

300 mm

300 mm

300 mm

300 mm

300 mm

Width

465 mm

465 mm

465 mm

465 mm

465 mm

465 mm

Height

465 mm

465 mm

465 mm

465 mm

465 mm

465 mm

Depth

255,5 mm

278 mm

231,5 mm

254 mm

255,5 mm

278 mm

Width with packaging

480 mm

480 mm

480 mm

480 mm

480 mm

480 mm

Height with packaging

480 mm

480 mm

480 mm

480 mm

480 mm

480 mm

Depth with packaging

330 mm

320 mm

330 mm

320 mm

330 mm

325 mm

EX designation in accordance with the ATEX Directive

Ex II 2 G

Ex II 2 G

Ex II 2 G

Ex II 2 G

Ex II 2 G

Ex II 2 G

EX designation in accordance with standard

Ex eb IIB + H2 T4 Gb / Ex h IIB + H2 T4 Gb

Ex eb IIB + H2 T4 Gb / Ex h IIB + H2 T4 Gb

Ex eb IIB + H2 T3 Gb / Ex h IIB + H2 T3 Gb

Ex eb IIB + H2 T3 Gb / Ex h IIB + H2 T3 Gb

Ex eb IIB + H2 T3 Gb / Ex h IIB + H2 T3 Gb

Ex eb IIB + H2 T3 Gb / Ex h IIB + H2 T3 Gb

Ta ambient temperature

-20 °C ≤ Ta ≤ +40 °C

-20 °C ≤ Ta ≤ +40 °C

-20 °C ≤ Ta ≤ +60 °C

-20 °C ≤ Ta ≤ +60 °C

-20 °C ≤ Ta ≤ +60 °C

-20 °C ≤ Ta ≤ +60 °C

IA/IN

3,4

3,4

3,4

3,4

8,5

8,5

Time tA

1390 sek

1390 sek

170 sek

170 sek

85 sek

85 sek

Operating mode

S1

S1

S1

S1

S1

S1

PTC DIN 44082

M 80

M 80

M 130

M 130

M 100

M 100

EC type examination certificate

TÜV-A 19 ATEX0102 X, IECEx EPS 19.0018X

TÜV-A 19 ATEX0102 X, IECEx EPS 19.0018X

TÜV-A 19 ATEX0102 X, IECEx EPS 19.0018X

TÜV-A 19 ATEX0102 X, IECEx EPS 19.0018X

TÜV-A 19 ATEX0102 X, IECEx EPS 19.0018X

TÜV-A 19 ATEX0102 X, IECEx EPS 19.0018X

Temperature class

T4

T4

T3

T3

T3

T3

Temperature class of insulating materials Th. Cl.

155 (F)

155 (F)

155 (F)

155 (F)

155 (F)

155 (F)

Packing unit

1 piece

1 piece

1 piece

1 piece

1 piece

1 piece

Range

C

C

C

C

C

C

GTIN (EAN)

4012799831747

4012799941200

4012799831754

4012799941217

4012799831761

4012799941224

Imax

not specified

not specified

not specified

not specified

1 A

1 A

* Blue markings show the differences between the products.

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings