DN 500

Three-phase AC fans, nominal size 500, air volume 5700 m³/h to 8700 m³/h (medium: dust)

DN 500 IM0013760.PNG Three-phase AC fans, nominal size 500, air volume 5700 m³/h to 8700 m³/h (medium: dust)

Below you can see a direct comparison of the products you have selected. Differences between the products are highlighted in blue.

ArticleDZQ 50/6 B Ex tDZS 50/6 B Ex tDZQ 50/4 B Ex tDZS 50/4 B Ex t
Product detailsProduct detailsProduct detailsProduct details
  • On the notes
  • On the notes
  • On the notes
  • On the notes
Product type Axial wall fan Axial wall fan Axial wall fan Axial wall fan
Article number: 0083.0214 0094.0213 0083.0215 0094.0214
Model

Square wall plate

Steel wall ring

Square wall plate

Steel wall ring

Air flow volume

5.320 m³/h

5.320 m³/h

8.200 m³/h

8.200 m³/h

Rotating speed

960 1/min

960 1/min

1.440 1/min

1.440 1/min

Speed controllable

Reversing capacity

Type of voltage

Three-phase AC

Three-phase AC

Three-phase AC

Three-phase AC

Rated voltage

400 V

400 V

400 V

400 V

Frequency

50 Hz

50 Hz

50 Hz

50 Hz

Nominal output

165 W

165 W

420 W

420 W

cosφ

0,41

0,41

0,74

0,74

Inom

0,56 A

0,56 A

0,82 A

0,82 A

Imax at UNominal

0,73 A

0,73 A

1,83 A

1,83 A

Degree of protection

IP 64

IP 64

IP 64

IP 64

Insulation class

F

F

F

F

Type of installation

Surface-mounted

Surface-mounted

Surface-mounted

Surface-mounted

Material

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Colour

galvanised

galvanised

galvanised

galvanised

Weight

18,4 kg

14,3 kg

24,01 kg

24,41 kg

Weight including packaging

22,36 kg

18,53 kg

28,12 kg

25,2 kg

Nominal size

500 mm

500 mm

500 mm

500 mm

Width

700 mm

700 mm

700 mm

700 mm

Height

700 mm

700 mm

700 mm

700 mm

Depth

269 mm

270 mm

293,5 mm

294,5 mm

Width with packaging

730 mm

720 mm

730 mm

730 mm

Height with packaging

730 mm

720 mm

730 mm

730 mm

Depth with packaging

440 mm

420 mm

420 mm

435 mm

EX designation in accordance with the ATEX Directive

Ex II 2 D

Ex II 2 D

Ex II 2 D

Ex II 2 D

EX designation in accordance with standard

Ex tb IIIB T135°C Db IP64 X / Ex h IIIB T135°C Db X

Ex tb IIIB T135°C Db IP64 X / Ex h IIIB T135°C Db X

Ex tb IIIB T200°C Db IP64 X / Ex h IIIB T200°C Db X

Ex tb IIIB T200°C Db IP64 X / Ex h IIIB T200°C Db X

Ta ambient temperature

-20 °C ≤ Ta ≤ +40 °C

-20 °C ≤ Ta ≤ +40 °C

-20 °C ≤ Ta ≤ +60 °C

-20 °C ≤ Ta ≤ +60 °C

IA/IN

3,1

3,1

4,6

4,6

Time tA

240 sek

240 sek

240 sek

240 sek

Operating mode

S1

S1

S1

S1

PTC DIN 44082

M 100

M 100

M 130

M 130

EC type examination certificate

TÜV-A 19 ATEX0102 X, IECEx EPS 19.0018X

TÜV-A 19 ATEX0102 X, IECEx EPS 19.0018X

TÜV-A 19 ATEX0102 X, IECEx EPS 19.0018X

TÜV-A 19 ATEX0102 X, IECEx EPS 19.0018X

Temperature class

T135°C

T135°C

T200°C

T200°C

Temperature class of insulating materials Th. Cl.

155 (F)

155 (F)

155 (F)

155 (F)

Packing unit

1 piece

1 piece

1 piece

1 piece

Range

C

C

C

C

GTIN (EAN)

4012799832140

4012799942139

4012799832157

4012799942146

* Blue markings show the differences between the products.

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings