ERD, DRD - DN 355

Three-phase and single-phase AC fans, DN 355, air volume from 3400 m3/h to 5200 m3/h

ERD, DRD - DN 355 IM0009963.PNG Three-phase and single-phase AC fans, DN 355, air volume from 3400 m3/h to 5200 m3/h

Below you can see a direct comparison of the products you have selected. Differences between the products are highlighted in blue.

ArticleERD 35/6 BDRD 35/6 BDRD 35/4 BDRD 35/64 B
Product detailsProduct detailsProduct detailsProduct details
  • On the notes
  • On the notes
  • On the notes
  • On the notes
Product type Centrifugal roof fan Centrifugal roof fan Centrifugal roof fan Centrifugal roof fan
Article number: 0087.0007 0087.0107 0087.0106 0087.0152
Air flow volume

3.400 m³/h

3.500 m³/h

5.200 m³/h

3.500 m³/h / 5.000 m³/h

Speed controllable

Reversing capacity

-

-

-

-

Rated voltage

230 V

400 V

400 V

400 V

Degree of protection

IP 55

IP 55

IP 55

IP 55

Installation site

Roof

Roof

Roof

Roof

Installation position

vertical

vertical

vertical

vertical

Material

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Sheet steel, galvanised

Weight

60

54

53,5

59

Weight including packaging

60 kg

60 kg

60,5 kg

60 kg

Shutter

integrated

integrated

integrated

integrated

Type of shutter

Airstream-operated opening/closing

Airstream-operated opening/closing

Airstream-operated opening/closing

Airstream-operated opening/closing

Nominal size

355 mm

355 mm

355 mm

355 mm

Width with packaging

840 mm

830 mm

840 mm

840 mm

Height with packaging

640 mm

635 mm

625 mm

630 mm

Depth with packaging

840 mm

835 mm

840 mm

840 mm

Airstream temperature at IMax

60 °C

60 °C

60 °C

60 °C

Packing unit

1 piece

1 piece

1 piece

1 piece

Range

C

C

C

C

GTIN (EAN)

4012799870074

4012799871071

4012799871064

4012799871521

Rotating speed

not specified

930 1/min

1.425 1/min

930 1/min / 1.425 1/min

Type of voltage

not specified

Three-phase AC

Three-phase AC

Three-phase AC

Nominal output

not specified

345 W

1.130 W

400 W / 1.200 W

Inom

not specified

0,8 A

2,4 A

0,9 A / 2,1 A

Imax

not specified

1,1 A

3,6 A

0,9 A / 2,1 A

Insulation class

not specified

F

F

F

Pole-changeable

not specified

-

-

Mains cable

not specified

5 x 1,5 mm²

5 x 1,5 mm²

5 x 1,5 mm²

Airstream temperature at nominal current

not specified

-20 °C up to 60 °C

-20 °C up to 60 °C

-20 °C up to 60 °C

Number of poles at high speed

not specified

not specified

not specified

4

Number of poles at low speed

not specified

not specified

not specified

6

* Blue markings show the differences between the products.

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings