Surface-mounted fan

ER-AP 100 H

Article number: 0084.0174
Manufacturer: MAICO
Surface-mounted fan for air extraction, air volume 100 m³/h, with humidity control and base load circuit
Application examples: Bathroom, Kitchen, Multiple family unit, Day room, Dining room
Product data sheet
ER-AP 100 H IM0009918.PNG Surface-mounted fan for air extraction, air volume 100 m³/h, with humidity control and base load circuit
ER-AP 100 H IM0008446.PNG Surface-mounted fan for air extraction, air volume 100 m³/h, with humidity control and base load circuit
ER-AP 100 H IM0007254.PNG Surface-mounted fan for air extraction, air volume 100 m³/h, with humidity control and base load circuit

Characteristic curve

ER-AP 100 H - Characteristic curve

Dimensioned drawing

ER-AP 100 H - Dimensioned drawing [mm]

Technical data

ER-AP 100 H - Technical data

Article ER-AP 100 H
Model Humidity control
Air flow volume 35 m³/h / 100 m³/h
Rotating speed 900 1/min / 1.850 1/min
Air direction Air extraction
Speed controllable
SEC average -21,88 kWh/(m²*a)
Rated voltage 230 V
Frequency 50 Hz
Power consumption 10 W / 29 W
Imax 0,09 A / 0,15 A
Degree of protection IP X5
Mains cable 3/5 x 1.5 mm²
Installation site Wall / Ceiling
Type of installation Surface-mounted
System type Decentralised
Material Synthetic material
Colour Traffic white, similar to RAL 9016
Weight 1,92 kg
Weight including packaging 2,48 kg
Filter class ISO Coarse 30 % (G2)
Fire protection No
Connection diameter 75 mm / 80 mm
Width 236 mm
Height 236 mm
Depth 217,5 mm
Width with packaging 255 mm
Height with packaging 280 mm
Depth with packaging 255 mm
Airstream temperature at IMax 40 °C
Overrun time 6 min
Overrun time / Overrun time available when using an optional switch (e.g. light switch)
Sound pressure level 33 dB(A) / 49 dB(A) / Specifications in accordance with DIN 18017-3 at an equivalent absorption area AL = 10 m.2
Approval number Z-51.1-42
Packing unit 1 piece
Range B
GTIN (EAN) 4012799841746
Article number 0084.0174

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA7, low (dB(A))

37

LWA7, high (dB(A))

53

LWA7= housing and free inlet sound power level in dB.

Accessories / Spare parts

ER-AP 100 H - Accessories / Spare parts

Specific accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
Flexible aluminium duct AFR - - -
Roof outlet DF - - -
Roofing tile DP - - -
Mounting clamp BS - - -
Rain protection grille RG - - -
Roofing tile DP - - -
Outside air opening ALD 10 0152.0054 on request
  • On the notes
Outside air opening ALD 125 Discontinued product 0152.0067 on request
  • On the notes
Outside air opening ALD 125 VA Discontinued product 0152.0068 on request
  • On the notes
Outside air opening ALD 160 Discontinued product 0152.0069 on request
  • On the notes
Outside air opening ALD 160 VA Discontinued product 0152.0070 on request
  • On the notes
Door ventilation grille MLK 30 white 0151.0123 on request
  • On the notes
Door ventilation grille MLK 45 white 0151.0126 on request
  • On the notes
Radio switch XS 1 No longer available for delivery 0157.0344 on request
  • On the notes
Radio receiver XE 1 No longer available for delivery 0157.0343 on request
  • On the notes
Outside air opening ALD 10 T No longer available for delivery 0152.0055 on request
  • On the notes
Outside air opening ZE 45 F white No longer available for delivery 0152.0044 on request
  • On the notes

Spare parts

Product description

Productdescription

ER-AP 100 H

short description

Surface-mounted fan for air extraction, air volume 100 m³/h, with humidity control and base load circuit

Product description

Model with humidity control and base load circuit

  • Barrier-free product, as automatic switching on/off is possible via humidity control.
  • Fully automatic intelligent humidity control.
  • Switch-on humidity does not have to be set. Fan independently monitors the room air humidity and extracts air automatically.
  • Not speed controllable.
  • Not suitable for second room air extraction.
  • Can be operated manually via a switch, e.g. full load is switched on using a light switch.
  • Standard switching: Fan runs in base load operation, humidity control is active, full load operation when the switch-on point is exceeded, base load operation when humidity falls below switch-off point.
  • More switching variants: Fan operation with or without base load operation; manual activation of full load; the fan is switched on/off using a switch.
  • Activation of full load using light switch and a fan overrun control linked to this (15 minute overrun time).
  • The fan runs until the air humidity in the room has fallen below the switch-off humidity level. After 60 min at the latest, the overrun time is activated and the fan is then switched off.

Features

  • Surface-mounted fan with ISO Coarse 30 % (G2) filter for air extraction in open-plan kitchens, bathrooms or WCs.
  • DN 75/80 plastic blowout socket with plastic airstream-operated backflow preventer.
  • Plastic backflow preventer also serves as a cold smoke preventer.
  • Housing can be rotated, so the blowout socket can be connected to the main duct at the top left or top right.
  • Trouble-free filter change without tools.
  • Simple and quick installation of the fan in the housing via the snap-on attachment and the electrical plug connector.
  • Colour: traffic white, similar to RAL 9016.
  • All MAICO ER units have an IP X5 degree of protection and can be installed in area 1 in accordance with DIN VDE 0100-701, even with water jets. For details see planning instructions.
  • Protection class II.
  • The extremely steep characteristic curve shows the high pressure capacity of the ER fans.
  • Robust energy-saving capacitor motor.
  • Motor with thermal overload protection.
  • Maintenance-free, with enclosed ball bearings on both sides.
  • Volumetric flow characteristic curve and air leakage rate checked by TÜV Bayern e.V (German Technical Inspection Agency). Air leakage rate < 0.01 m³/h.
  • Shaft level difference according to DIN 52210-6, tested by IAB Oberursel (The Institute for Acoustics and Building Physics in Germany).
  • With VDE symbol.
  • National technical approval, approval no.: Z-51.1-42;
  • Certificates of approval on request or on our website – www.maico-ventilatoren.com.

Table of contents

Wiring diagram

ER-AP 100 H - Wiring diagram

The fan always runs at the base load. If the humidity is higher than the switch-on humidity, the fan will automatically switch to full load.



Switching option 1

Fan always runs at base load. If humidity is higher than the switch-on humidity, the fan will automatically switch to full load. Additionally, it is possible to manually switch to full load with S1 switch.

Using a 1-pin switch can cause reverse polarity voltages. Combination with an X2 capacitor necessary!



Switching option 2

The fan is switched manually to base load with switch S1. If humidity is higher than the switch-on humidity, the fan will automatically switch to full load.



Switching option 3

The fan is manually switched on and off with switch S1. The fan always overruns until the air humidity in the room has fallen below the switch-off humidity level.



Predecessor - successor

ER-AP 100 H - Successor

Product type Name Art. No. Action
Surface-mounted housing ER GH AP 0084.0352
  • On the notes

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings