Semi-centrifugal duct fan

ERM 22

No longer available for delivery
Article number: 0080.0204
Manufacturer: MAICO
Semi-centrifugal duct fan, single-phase AC, with 2 reducers to DN 200
Application examples: Commercial premises, Canteen, Air extraction system, Workshop, Workplace air extraction system
Product data sheet
ERM 22 IM0009885.PNG Semi-centrifugal duct fan, single-phase AC, with 2 reducers to DN 200

Characteristic curve

ERM 22 - Characteristic curve

Dimensioned drawing

ERM 22 - Dimensioned drawing [mm]

Technical data

ERM 22 - Technical data

Article ERM 22
Air flow volume 580 m³/h / Measured with 1 m duct on the inlet and outlet side
Rotating speed 2.750 1/min
Speed controllable
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Nominal output 165 W
Inom 0,7 A
Imax 0,95 A
Degree of protection IP 55
Insulation class F
Mains cable 3 x 1,5 mm²
Housing material Synthetic material, shock-resistant
Colour Pearl white, similar to RAL 1013
Weight 5,6 kg
Weight including packaging 5,48 kg
Nominal size 200 mm
Width with packaging 290 mm
Height with packaging 235 mm
Depth with packaging 285 mm
Airstream temperature at nominal current -20 °C up to 60 °C
Airstream temperature at IMax -20 °C up to 60 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799802044
Article number 0080.0204

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, S1 (dB(A))

25

26

22

24

30

35

21

15

37

LWA2, S2 (dB(A))

23

36

34

35

38

41

32

23

45

LWA2, S3 (dB(A))

28

45

47

48

48

51

43

39

55

LWA2, S4 (dB(A))

30

52

52

53

53

55

48

46

61

LWA2, S5 (dB(A))

36

56

55

57

56

57

51

49

63

LWA5, S1 (dB(A))

19

26

29

34

38

36

27

24

42

LWA5, S2 (dB(A))

28

38

42

47

48

47

41

34

53

LWA5, S3 (dB(A))

35

48

53

60

60

60

53

49

66

LWA5, S4 (dB(A))

37

52

56

65

65

64

58

54

70

LWA5, S5 (dB(A))

39

56

58

67

66

66

60

56

72

LWA6, S1 (dB(A))

23

27

28

36

38

37

32

23

43

LWA6, S2 (dB(A))

29

38

42

50

51

49

46

33

56

LWA6, S3 (dB(A))

36

47

55

64

63

62

58

49

69

LWA6, S4 (dB(A))

38

51

61

69

68

67

64

56

74

LWA6, S5 (dB(A))

41

53

63

72

71

70

66

59

77

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

Accessories

ERM 22 - Accessories

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Mounting foot FUM 22 0036.0004 on request
  • On the notes
Flexible cuff ELM 20 No longer available for delivery 0092.0118 on request
  • On the notes

General accessories

Product type Name Art. No. Price*(EUR) Action
Shutter AS 20 0151.0330 on request
  • On the notes
Automatic backflow preventer AVM 20 0093.0006 on request
  • On the notes
Tubular sound absorber RSR 20 Remaining parts 0092.0316 on request
  • On the notes
Tubular sound absorber RSR 20/50 Remaining parts 0092.0326 on request
  • On the notes
Tubular sound absorber RSR 20-1 0092.0597 on request
  • On the notes
Tubular sound absorber RSR 20/50-1 0092.0604 on request
  • On the notes
Water air heater WRH 20-2 0082.0119 on request
  • On the notes
Air filter TFE 20-4 0149.0078 on request
  • On the notes
Air filter TFE 20-7 0149.0053 on request
  • On the notes
5-step switch for TRE...S -2/ TR...S-2 5-step transformers ESS 20 0157.0749 on request
  • On the notes
Reducer REM 22/18 No longer available for delivery 0059.0634 on request
  • On the notes
Reducer REM 22/15 No longer available for delivery 0059.0635 on request
  • On the notes
SGM 22 No longer available for delivery 0059.0428 on request
  • On the notes
Air filter TFE 20-5 No longer available for delivery 0149.0062 on request
  • On the notes
Speed controller ST 2,5 No longer available for delivery 0157.0811 on request
  • On the notes
Speed controller STU 2,5 No longer available for delivery 0157.0815 on request
  • On the notes
Speed controller, distribution board STS 2,5 No longer available for delivery 0157.0255 on request
  • On the notes
5-step transformer TRE 1,6-1 No longer available for delivery 0157.0348 on request
  • On the notes
5-step transformer, control cabinet TRE 1,6 S No longer available for delivery 0157.0744 on request
  • On the notes

Product description

Productdescription

ERM 22

short description

Semi-centrifugal duct fan, single-phase AC, with 2 reducers to DN 200

Product description

Features

  • Reduced space requirement due to compact dimensions.
  • IP 55 degree of protection for horizontal installation positions or when the airstream direction is downwards.
  • Inlet and outlet side connection couplings for direct installation in ventilation ducts.
  • Semi-centrifugal impeller, favourable flow technology.
  • Inflow direction equals outflow direction. Thus resulting in simple installation.
  • Pearl white, similar to RAL 1013.

Air flow direction

  • Airstream and rotational directions are indicated by arrows marked on the fan housing

Motor

  • ERM 15: Shaded-pole motor
  • ERM 18: Capacitor motor
  • Speed controllable.
  • Operating capacitor in the terminal box is ready to be connected.
  • Thermal overload protection as a standard feature.
  • Potential-free terminal connections, which must be connected to e.g. an MVE 10 protective motor switch or the control circuit of a contactor.
  • Robust motor with ball bearings, maintenance-free.

Mounting instructions

  • Can be fitted in any position.
  • Use ELM flexible cuffs to prevent transfer of vibrations onto the duct system.

Electrical connection

  • Externally fitted terminal box with cable guide bushes.

Safety instructions

  • The fan may be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN ISO 13857 for fans with free inlet or free outlet. To do this, fit a SGM protective grille.

Special versions

  • The following special versions are available on request, at an extra cost:
    • Special voltages and frequencies.
    • PTC thermistor on terminals.
  • Information on operation at temperatures occasionally below -20°C available upon request.
  • Feasibility must be checked in each case.

Table of contents

Wiring diagram

ERM 22 - Wiring diagram

ERM.. with on and off switch

S1 - Off switch (to be supplied by the customer)

S2 - On switch (to be supplied by the customer)

K1 - Contactor US 16 T (to be supplied by the customer)





Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings