Final assembly kit

WRG 35H-SE

No longer available for delivery
Article number: 0082.0234
Manufacturer: MAICO
Fan unit with integrated hygrostat for WRG 35 single-room ventilation unit with heat recovery, 17 - 60 m³/h,... more information
Application examples: Apartment, Redevelopment, Flat occupying the whole of one floor, Tenant apartment, Single-family house
Product data sheet
WRG 35H-SE IM0009453.PNG Fan unit with integrated hygrostat for WRG 35 single-room ventilation unit with heat recovery, 17 - 60 m³/h, including internal cover and 2 x G4 filters, required accessory: Shell kit WRG 35 SR and RLS 5 room air control.

Characteristic curve

Dimensioned drawing

WRG 35H-SE - Dimensioned drawing [mm]

Dimensions of internal cover:

W x H x D: 380 x 380 x 45 mm

Technical data

WRG 35H-SE - Technical data

Article WRG 35H-SE
Air flow volume 17 m³/h / 30 m³/h / 45 m³/h / 60 m³/h
Speed controllable
Energy efficiency class A
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Maximum power consumption 2 W / 4 W / 6 W / 8 W
Imax 0,04 A / 0,05 A / 0,06 A / 0,07 A
Degree of protection IP X4
Electrical plug-type connection Screw connection
Integrated hygrostat
Installation site Wall
Installation position horizontal
System type Decentralised
Housing material Plastic EPP
Heat exchanger material Aluminium
Weight 4,7 kg
Weight including packaging 5,92 kg
Type of filter Dust filter
Filter class G4
Width 400 mm
Height 380 mm
Depth 400 mm
Width with packaging 401 mm
Height with packaging 400 mm
Depth with packaging 460 mm
Ambient temperature 40 °C
Heat recovery rate > 70 %
Heat exchanger construction type Cross flow
Sound pressure level 14 dB(A) / 25 dB(A) / 30 dB(A) / 37 dB(A) / Distance 3 m, Free-field conditions
Rated max. element normal difference in noise level Dn,w 39 dB
Packing unit 1 piece
Range K
GTIN (EAN) 4012799822349
Article number 0082.0234

Accessories

WRG 35H-SE - Accessories

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Air filter, replacement WRG 35-G4 0192.0452 on request
  • On the notes
Air filter, replacement WRG 35-F7 0192.0453 on request
  • On the notes
Shell kit WRG 35-SR No longer available for delivery 0192.0450 on request
  • On the notes
Extension sleeve WRG 35-VH No longer available for delivery 0192.0451 on request
  • On the notes
Compensating frame WRG 35-AR No longer available for delivery 0192.0454 on request
  • On the notes
Connection distributor WRG 35-AAD No longer available for delivery 0092.0501 on request
  • On the notes
Connecting duct WRG 35-TAK 5 No longer available for delivery 0092.0502 on request
  • On the notes
Connecting duct WRG 35-TAK 10 No longer available for delivery 0092.0503 on request
  • On the notes
Room air control RLS 5 AP No longer available for delivery 0157.0845 on request
  • On the notes
Room air control RLS 5 UP No longer available for delivery 0157.0846 on request
  • On the notes

Product description

Productdescription

WRG 35H-SE

short description

Fan unit with integrated hygrostat for WRG 35 single-room ventilation unit with heat recovery, 17 - 60 m³/h, including internal cover and 2 x G4 filters, required accessory: Shell kit WRG 35 SR and RLS 5 room air control.

Product description

Model with integrated hygrostat

  • RLS 5 room air control required.

Features

  • Complete fan unit for WRG 35 single-room ventilation unit with heat recovery, including internal cover and two G4 filters. WRG 35H-SE: With integrated hygrostat.
  • Accessories needed:
    • WRG 35-SR shell kit.
    • RLS 5 room air control.
    • Up to a maximum of 9 units can be controlled at the same time through a room air control.
  • Up to four RLS 5 room air controls can be connected to one unit. They are networked using a WRG 35-AAD connection distributor and WRG 35-TAK connection cables.
  • Suitable for continuous operation. Longer off times are not recommended.

Heat exchanger

  • Aluminium cross flow plate heat exchanger.
  • Separate air flows and therefore no transfer of odours etc.

Heat recovery fan

  • 2 axial DC fans. One fan each for supply air and exhaust air.
  • 4 ventilation levels with heat recovery:
    • 1 = minimum ventilation (17 m³/h)
    • 2 = normal ventilation (30 m³/h)
    • 3 = intensive ventilation 1 (45 m³/h)
    • 4 = intensive ventilation 2 (60 m³/h)
  • Further ventilation levels without heat recovery:
    • Supply air mode, i.e. supply air operation only at 30 m³/h (e.g. for cooling at night).
    • Exhaust air mode, i.e. exhaust air operation only at 30 m³/h (e.g. cross ventilation per living unit). To achieve this, the WRG 35 is e.g. switched to supply air mode in the bedroom and to exhaust air mode in the living room.
    • Level 0, the zero air level: Closes the external shutters if there are bad odours coming in from the outside. The unit continues to consume electricity.

Mounting instructions

  • Assembly involves 2 steps:
    • Fitting WRG 35-SR shell kit in a DN 360 core hole.
    • Integration of WRG 35-SE or WRG 35H-SE final assembly set.
  • The shell kit's wall sleeve is protected from contamination by plaster protective covers.
  • The drilling template supplied simplifies the process of installing the external cover.
  • The covers are easy to remove.
  • No need to lay ducts.
  • The system requires no adjustment.

Electrical connection

  • When delivered, the unit is assembled and ready for service.
  • The electrical supply is connected using the terminal provided.
  • Connection to RLS 5 room air control using six-pin control cable (included in scope of supply for room air control).

Condensation drain

  • The condensation drain is fitted ready for use.
  • The condensate is removed via the external cover.

Table of contents

Wiring diagram

WRG 35H-SE - Wiring diagram

WRG 35H-SE final assembly kit with RLS 5 room air control

RF - To be provided by customer for air-ventilated fireplaces

SF - Fireplace signal

TS - Customer's isolating switch, on/off switch, VDE 0700 T1 7.12.2

SL - 6-core control cable

Humi - humidity sensor

FS - Frost protection sensor, special equipment



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings