Final assembly kit

PPB 30 K

Article number: 0095.0246
Manufacturer: MAICO
Final installation kit for PushPull Balanced PPB 30 K single-room ventilation unit with heat recovery,... more information

Product data sheet
PPB 30 K IM0018181.PNG Final installation kit for PushPull Balanced PPB 30 K single-room ventilation unit with heat recovery, comprising 2 fans, 2 ceramic heat exchangers, internal cover with 2 ISO Coarse 45 % (G3) filters, comfort version: with integrated humidity sensor, accessories needed: Shell sleeve, external cover and RLS 45 K room air control, optional accessories: extension kit, wall block, compensating frame and sensors

Characteristic curve

Dimensioned drawing

PPB 30 K - Dimensioned drawing [mm]

  1. Wall sleeve centre
  2. Fixing holes
  3. Cable entry

Technical data

PPB 30 K - Technical data

Article PPB 30 K
Model Comfort version, integrated humidity sensor
Air flow volume 5 m³/h / 12 m³/h / 18 m³/h / 22 m³/h / 26 m³/h
SEC average -40,23 kWh/(m²*a)
Energy efficiency class A
Rated voltage 12 V DC
SPI value in accordance with DIN EN 13141-8 0,19 Wh/m³
Maximum power consumption 1,7 W / 2,5 W / 3,4 W / 4,4 W / 5,3 W
Degree of protection IP X4
Installation position horizontal
System type Decentralised
Material Synthetic material
Housing material Synthetic material
Heat exchanger material Ceramic
Colour Traffic white, similar to RAL 9016
Weight 4,69 kg
Weight including packaging 5,71 kg
Type of filter Outside and exhaust air filter
Filter class ISO Coarse 45 % (G3)
Connection diameter 160 mm
Width 275 mm
Height 275 mm
Depth 410 mm
Width with packaging 300 mm
Height with packaging 330 mm
Depth with packaging 475 mm
Wall has to be broken through 162 to 182 mm
Minimum wall thickness 320 millimeters
Degree of heat provision with reference volumetric flow according to DIN EN 13141-8 73,3 %
Required room air control RLS 45 K
Sound pressure level 23 dB(A) / 35 dB(A) / 43 dB(A) / 48 dB(A) / 51 dB(A) / Distance 1 m, free-field conditions
Rated max. element normal difference in noise level Dn,w 37 dB
Packing unit 1 piece
Range K
GTIN (EAN) 4012799952466
Article number 0095.0246

Product description

Productdescription

PPB 30 K

short description

Final installation kit for PushPull Balanced PPB 30 K single-room ventilation unit with heat recovery, comprising 2 fans, 2 ceramic heat exchangers, internal cover with 2 ISO Coarse 45 % (G3) filters, comfort version: with integrated humidity sensor, accessories needed: Shell sleeve, external cover and RLS 45 K room air control, optional accessories: extension kit, wall block, compensating frame and sensors

Product description

Approvals and certificates

  • Test report in accordance with EN 13141-8.
  • Entry in TZWL bulletin.

Heat exchanger

  • Thanks to the high-performance heat exchangers and high-efficiency EC fans, the units achieve a degree of heat provision of 73 % at reference volumetric flow according to EN 13141-8.

Installation instructions

  • Mounting involves 2 steps:
    • Installation of the PP 45 RHK (DN 160) or PP 45 RHL (DN 160) shell sleeve and an external cover in a DN 160 core drill hole with an inclination of 1-2 %.
    • We recommend drilling a DN 182 core hole and using the polystyrene shims provided to align the inclination of the sleeve.
    • The shell sleeve is protected from contamination by plaster protective covers.
    • Then the final assembly kit is integrated.
    • No ducts have to be laid and the system does not have to be adjusted.

Electrical connection

  • When delivered, the unit is assembled and ready for service.
  • The electrical connection is made using a plug connection.
  • Connection to RLS 45 K or RLS 45 O room air control using pluggable control cables.
  • The 12 VDC power cable of the RLS 45 K / RLS 45 O room air control to the unit is also the control cable.

Condensation drain

  • The condensate is removed via an integrated condensation drip edge in the external cover.

Special features

  • The PPB 30 K unit is a perfect supplement for PP 45 K/O units to set up a ventilation system according to DIN 1946-6 via a central control system (RLS 45 K).
  • The PPB 30 K units have a humidity sensor as standard and are primarily designed for installation in the exhaust air rooms. The IP X4 degree of protection facilitates the choice of installation location in the bathroom.
  • The energy efficiency of the PPB 30 K is impressive with an SPI value of 0.19 Wh/m³.
  • Due to the energy-saving motors and a very good sensor-guided operation, the devices achieve energy efficiency class A.
  • The PPB 30 K unit can be operated in 5 ventilation levels 5/12/18/22/26 m³/h and 3 operating modes (continuous ventilation with heat recovery, cross-ventilation without heat recovery) and automatic operating mode.
  • The recommended combination option is 2 x or 4 x PP 45 K/O + 1 x PPB 30 K + 1 x RLS 45 K.
  • In this case, the PPB 30 K unit can be operated in two different operating modes. When in automatic mode, the unit runs completely independently depending on the humidity value of the integrated sensor. When in automatic mode, only the “External Off” and “Ventilation level 0” commands are executed by the RLS 45 K room air control system. In system operation, the unit works completely according to the specifications of the RLS 45 K room air control system. Only in the event of a humidity load (adjustable limit value) does the unit disconnect from the system and start dehumidification.
  • Automatic dehumidification can be set as intensive ventilation mode (level 5 with heat recovery) or as exhaust air mode (45m³/h without heat recovery).
  • In the event of odours, intensive ventilation mode (level 5 with heat recovery) or exhaust air mode (45m³/h without heat recovery) can also be triggered manually with a button/switch. The duration of this function is adjustable (factory setting = 10 min).
  • If the PPB 30 K is running in exhaust air mode, the PP 45 K/O units connected to the RLS 45 K room air control system ensure the necessary supply air. PPB 30 K and exhaust air units (e.g. ER/ECA) cannot be combined with an RLS 45 K room air control.
  • Clear commissioning software, when using the RLS 45 K control system, facilitates the commissioning of the PPB 30 K units. The settings can be stored as a profile and transferred to other controllers.
  • Flow-optimised external covers in the accessories range keep the exhaust air away from the external façade.

Features

  • Final installation kits for PushPull Balanced PPB 30 single-room ventilation unit with two fans, two ceramic heat exchangers, internal cover and two integrated ISO Coarse 45 %(G3) filters such that the air is filtered in both directions.

Required accessories

  • PP 45 RHK or PP 45 RHL shell sleeve
  • PPB 30 AK, PPB 30 AE, PPB 30 AW or PPB 30 AS external cover
  • RLS 45 K room air control. An RLS 45 K room air control can be used to construct a wired ventilation system comprising PPB 30 and PP 45 units. The maximum number of fans used is 6. Various combinations are therefore possible, e.g. 2 x PP 45 K/O + 1 x PPB 30 K + 1 x RLS 45 K or 3 x PPB 30 K + 1 x RLS 45 K. A combination of PPB 30 K and RLS 45 O is not permitted.

Optional accessories

  • PPB 30 VS extension kit
  • PP 45 MB wall block
  • PPB 30 ARE and PPB 30 ARW compensating frames
  • PPB 30 ARE BB and PPB 30 ARW BB fixing plates for compensating frame
  • PP 45 HYI and PP 45 HY humidity sensor
  • PP 45 CO2 CO2 sensor
  • PP 45 VOC sensor
  • Air filter, PPB 30 G3 replacement
  • The RLS 45 K room air control can be extended with the PP 45 HYI humidity sensor or with PP 45 HY, PP 45 CO2 and PP 45 VOC external sensors. The units therefore attain the A energy efficiency class.
  • The RLS 45 K room air control can be operated in 5 ventilation levels 5/12/18/22/26 m³/h and 3 operating modes (continuous ventilation with heat recovery, cross-ventilation without heat recovery) and automatic operating mode.

Table of contents

Wiring diagram

PPB 30 K - Wiring diagram

RLS 45 K - PushPull 45 Comfort room air control

PP 45 K - PushPull 45 Comfort fan unit

PPB 30 K - PushPull Balanced 30 Comfort fan unit

Fan 1.1 - fan unit 1, unit pair 1

Fan 2.1 - fan unit 2, unit pair 1

Fan 1.2 - fan unit 1, unit pair 2

Fan 2.2 - fan unit 2, unit pair 2

S1 - Button/switch for additional function (sleep, intensive, disbalance, safety function)

UP-L - Recessed-mounted distributor connection, connection of all fan units in star shape to distributor

W-F1 - Fan 1 control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. length to distributor 4m.

W-F2 - Fan 2 control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. length to distributor 4m.

W-B1 - Bus PPB control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. length to distributor 4m.

W1.X - Fan unit control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25m.

W2.X - Fan unit control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25m.

W-PPB - BBP 30 (bus) control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25m.

W3 - Connecting cable switch/pushbutton for activation of special functions (exhaust air mode, intensive ventilation), recommended control cable LiYY 2*0.5 mm². Max. cable length 25 metres.



PP 30 K - PPB 30 Comfort fan unit

VAP-K - Comfort fan circuit board

PPB 30 - Fan 1 - Fan 1 connecting cable

PPB 30 - Fan 2 - Fan 2 connecting cable

S1 - Switch/pushbutton for exhaust air mode/intensive ventilation (function/times selected via PushPull IBS)

W-PPB - PPB 30 K connecting cable to RLS 45 K via bus (RS-485), recommended control cable J-Y(ST)Y 2x2x0.8mm². Max. cable length to the PPB 30 K, 25 metres from the star point.

W3 - Connecting cable switch/pushbutton for activation of special functions (exhaust air mode, intensive ventilation), recommended control cable LiYY 2*0.5 mm². Max. cable length 25 metres.



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings