Sound-insulated ventilation box

KFR 9030-K

No longer available for delivery
Article number: 0080.0967
Manufacturer: MAICO
Sound-insulated Flatbox for supply air with centrifugal fan, shutter, air filter, water-air heater and cooling... more information

Product data sheet
KFR 9030-K IM0011762.PNG Sound-insulated Flatbox for supply air with centrifugal fan, shutter, air filter, water-air heater and cooling register, channel size 900 mm x 300 mm

Characteristic curve

KFR 9030-K - Characteristic curve

KFR 9030-K - Characteristic curve Water pressure losses in the heat register

KFR 9030-K - Characteristic curve Cooling register water pressure losses

Dimensioned drawing

KFR 9030-K - Dimensioned drawing [mm]

  1. Mounting bracket (variable position)
  2. Warm water connection for water-air heater 3/4" AG (connection also possible on opposite side)
  3. Cooling register connection
  4. Mounting handle
  5. Electrical connections
  6. Terminal box for fan
  7. Servomotor shutter

Technical data

KFR 9030-K - Technical data

Article KFR 9030-K
Air flow volume 3.550 m³/h / Required Delta pfs min = 300 Pa
Rotating speed 2.700 1/min
Air direction Ventilation
Speed controllable
Cooling register design Cold water register
Rated voltage 230 V
Nominal output 1.620 W
Imax 8,3 A
Degree of protection IP 43
Operator unit degree of protection IP 00
Weight 123 kg
Weight including packaging 130,68 kg
Filter class F5
Channel dimension 900 mm x 300 mm
Width with packaging 1.200 mm
Height with packaging 820 mm
Depth with packaging 1.200 mm
Airstream temperature at nominal current 45 °C
Airstream temperature at IMax 45 °C
Packing unit 1 piece
Range K
GTIN (EAN) 4012799809678
Article number 0080.0967

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, high (dB(A))

51

53

44

45

45

45

41

57

LWA5, high (dB(A))

58

64

68

67

68

62

51

74

LWA6, high (dB(A))

61

67

66

57

55

62

64

72

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

Accessories

KFR 9030-K - Accessories

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Air filter, replacement KFF 9030-5 0093.1216 on request
  • On the notes
Air filter, replacement KFF 9030-7 0093.1219 on request
  • On the notes

General accessories

Product type Name Art. No. Price*(EUR) Action
External grille LZP-R 93 No longer available for delivery 0151.0388 on request
  • On the notes
Flexible coupling ELP 93 No longer available for delivery 0092.0263 on request
  • On the notes
Channel sound absorber KSP 93/28 No longer available for delivery 0092.0504 on request
  • On the notes

Product description

Productdescription

KFR 9030-K

short description

Sound-insulated Flatbox for supply air with centrifugal fan, shutter, air filter, water-air heater and cooling register, channel size 900 mm x 300 mm

Product description

KFR-K, KFD-K supply air model with cooling function

  • Sound-insulated Flatbox for ventilation.
  • With fan, shutter with servomotor, air filter, water-air heater and cooling register.
  • With control unit for supply and exhaust air unit.
  • Connections for water-air heater and cooling register, can either be positioned in one or the other longitudinal side.

Features

  • Compact unit for supply or exhaust air.
  • Housing has 30 mm of rock wool thermal and sound insulation.
  • Internal pressure losses are very low thanks to large flow-through areas. The housings are very smooth on the inside and outside and air-tight. This results in very quiet operations, few internal air noises and makes them easy to clean.
  • No elaborate wiring or installation of attachments needed since all components are fitted ready for use.
  • Control unit included in the scope of delivery of supply air unit.
  • Configuration information for water/air heaters can be accessed online.
  • IP 43 degree of protection.

Control unit

  • One control unit can be used to jointly control a supply air and exhaust air flat box.
  • Supply air flat box KFR / KFD and KFR-K / KFD-K: Control unit included in scope of delivery.
  • Exhaust air flat box KFR-A / KFD-A: No control unit included, controlled using control unit of supply air flat box or transformer.
  • If there is no KFR-A / KFD-A connected to the control unit, a 230 V transformer-type controllable fan can also be controlled instead (e.g. EKR, ESQ). Note: The power consumption of the exhaust air unit must not exceed that of the supply air unit.
  • The control unit takes on the following functions:
    • Selection of operating mode (supply air/circulating air).
    • 3 levels of fan control
    • Indication of current operating mode and setpoint temperature.
    • Specification of setpoint temperature on control unit.
    • Activation of servomotor, e.g. of heating circuit or cooling circuit.
    • Release signal on refrigeration machine.
    • Activation of a heating circulation pump.
    • Fault indicator with LED and error code on control unit.
    • Minimum and maximum limitation of supply air temperature.
    • Frost protection monitoring of water-air heater.
    • Air filter monitoring using differential pressure measurement.
    • Room temperature sensor integrated on control unit.
    • Activation of servomotor for shutter.

Mounting instructions

  • Due to the efficient sound and thermal insulation, the unit can be fitted directly in suspended ceilings.
  • Mounting bracket included in scope of delivery.
  • Fit horizontally only.

Table of contents

Wiring diagram

KFR 9030-K - Wiring diagram

KFR 9030, KFR 9030-K and KFR 9030 F wiring diagram

ZV - supply air fan

AV - exhaust fan

TK1 - thermal contact for supply air fan

TK2 - thermal contact for supply air fan

TK3 - thermal contact for exhaust fan

TK4 - thermal contact for exhaust fan

R1 - frost protection monitoring

R2 - NTC temperature sensor

FG - unit release, potential-free contact

FS - control unit

H - heating

P - circulation pump

FK - refrigeration machine release

S - unit fault

KL - shutter drive

U - supply 1 x 230 V / N / 50 Hz

SE - external 16 A fuse



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings