Air filter

TFE 16-5

No longer available for delivery
Article number: 0149.0061
Manufacturer: MAICO
Air filter for duct installation, DN 160

Product data sheet
TFE 16-5 IM0009966.PNG Air filter for duct installation, DN 160

Characteristic curve

TFE 16-5 - Characteristic curve Pressure losses

  1. TFE 10-5 to TFE 16-5
  2. TFE 20-5
  3. TFE 25-5
  4. TFE 31-5 and TFE 35-5
  5. TFE 40-5

Dimensioned drawing

TFE 16-5 - Dimensioned drawing [mm]

A: 160 mm
B: 300 mm
C: 360 mm
D: 300 mm
E: 300 mm
F: 330 mm

Technical data

TFE 16-5 - Technical data

Article TFE 16-5
Installation position vertical / horizontal
Housing material Sheet steel, galvanised
Weight 3,875 kg
Weight including packaging 4,38 kg
Filter class F5
Nominal size 160 mm
Width 360 mm
Height 330 mm
Depth 300 mm
Width with packaging 405 mm
Height with packaging 405 mm
Depth with packaging 415 mm
Ambient temperature 80 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799490616
Article number 0149.0061

Accessories / Accessories of

TFE 16-5 - Accessories / Accessories of

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Air filter, replacement RF 10/16-5 0093.0875 on request
  • On the notes

General accessories

Product type Name Art. No. Price*(EUR) Action
Differential pressure controller DW 1000 0157.0752 on request
  • On the notes

is a special accessory of

is a general accessory of

Product type Name Art. No. Price*(EUR) Action
Centrifugal duct fan ERR 16/1 0080.0273 on request
  • On the notes
Centrifugal duct fan ERR 16/1 S 0080.0274 on request
  • On the notes
Centralised ventilation unit WS 160 Flat - - -
Centralised ventilation unit WS 300 Flat - - -
Centralised ventilation unit WS 320 - - -
Centralised ventilation unit WS 470 - - -
Centralised ventilation unit WR 310 0095.0220 on request
  • On the notes
Centralised ventilation unit WR 310 R 0095.0260 on request
  • On the notes
Centralised ventilation unit WR 410 0095.0228 on request
  • On the notes
Centralised ventilation unit WR 410 R 0095.0261 on request
  • On the notes
Sound-insulated ventilation box ESR 16-3 EC New development 0080.1001 on request
  • On the notes
Diagonal fan HDR 16 Discontinued product 0080.0539 on request
  • On the notes
Diagonal fan HDR 16 EC Discontinued product 0080.0543 on request
  • On the notes
Diagonal fan ERK 160 Remaining parts 0080.0180 on request
  • On the notes
Sound-insulated ventilation box ESR 16 EC No longer available for delivery 0080.0085 on request
  • On the notes
Centralised ventilation unit WS 250 No longer available for delivery 0095.0050 on request
  • On the notes
Centralised ventilation unit WR 300 No longer available for delivery 0095.0078 on request
  • On the notes
Centralised ventilation unit WR 400 No longer available for delivery 0095.0079 on request
  • On the notes
Aeronom room air system WRG 300 EC No longer available for delivery 0082.0060 on request
  • On the notes
Centralised ventilation unit WRG 300 EC No longer available for delivery 0082.0062 on request
  • On the notes
Centrifugal duct fan ERR 16/1 N No longer available for delivery 0080.0867 on request
  • On the notes
Sound-insulated ventilation box ESR 16/1 No longer available for delivery 0080.0282 on request
  • On the notes
Sound-insulated ventilation box ESR 16-2 No longer available for delivery 0080.0611 on request
  • On the notes
Sound-insulated ventilation box ESR 16-2 No longer available for delivery 0080.0057 on request
  • On the notes
Sound-insulated ventilation box ESR 16-2 S No longer available for delivery 0080.0618 on request
  • On the notes
Sound-insulated ventilation box ESR 16-2 EC No longer available for delivery 0080.0711 on request
  • On the notes

Product description

Productdescription

TFE 16-5

short description

Air filter for duct installation, DN 160

Product description

  • Air filter for ventilation systems.
  • Inspection lid can be removed for easy filter exchange.
  • With synthetic fibre filter insert.
  • Panel filter.
  • Filter insert not regenerable.
  • With rubber sealing ring on the air connection sockets.
  • TFE ...-5: Filter class F5, accessories for replacement filter RF...-5
  • TFE ...-7: Filter class ISO ePM1 50 % (F7), accessories for replacement filter RF...-7
  • Recommended accessories: DW 1000 differential pressure controller.

Installation instructions

  • Monitor filter resistance using DW 1000 differential pressure controller.

Table of contents

Wiring diagram

TFE 16-5 - Wiring diagram

Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings