Installation information for ER-UP/ G housing
(also Requirements in line with approval and approval)
ER-UP/G are equipped with a plastic housing without fire protection equipment. The ER-UP/G housing may be installed in the following installation positions:
- Wall installation With air outlet direction (exhaust socket) upwards, to the right, to the left or to the rear. Installation with mounting support.
- Ceiling installation and suspended ceiling: Installation with mounting support.
- Ceiling installation and non-suspended ceiling: Mounting directly on the ceiling.
Suitable mounting material is to be provided by the customer.
The plastic shutter should be prepared according to these instructions so that it closes fully sealed in the installation position.
The housing must be inserted without any distortion. Failure to do so will mean that the fan insert cannot engage correctly in the housing and the degree of protection stated on the rating plate is no longer ensured.
Break open the housing segment [S] below to use the ER-ZR second room connection set or the ER-AS extraction socket.
A toilet seat air extraction unit is connected to the housing using the ER-AS extraction socket (DN 75/80).
Use ER-MO expanded rubber for acoustic insulation of thin ceilings capable of resonance (System and accessory components).