ER-UP/G wall installation, second room
6 | Protective grille |
7 | Filter mat, filter class G2 |
8 | Adapter |
9 | Suction duct, second room connection: flexible aluminium duct AFR 75/AFR 80 |
10 | Installation socket for second room extraction DN 75/80 |
37 | UPM 60/100 mounting support |
40 | ER-MO expanded rubber |
X4 | Clamping band or steel threaded rod with duct clamp |
- Cut out housing segment on the marking using a knife.
The unit will be damaged/function will be impaired by incorrect air if the installation socket is inserted incorrectly [11.1].
Degree of protection is no longer guaranteed.
- Correctly insert installation socket up to stop. This must audibly engage.
- Place installation socket in housing. The edge of the socket must click into place on the wall of the housing.
- Install housing as described above for single room.
- Connect suction duct with installation socket sealed for ventilation.
- Produce fixing holes for adapter and insert dowels.
- Connect adapter to suction duct, e.g. with cold-shrink tape.
- Secure adapter to the wall.
- Insert filter mat and locate the internal grille in the correct position.