Diagonal fan

EDR 45

Article number: 0080.0661
Manufacturer: MAICO
On request
Diagonal fan for duct installation, DN 450
Application examples: Machine extraction unit, Workplace air extraction system, Production site, Storage facility, Laboratory
Product data sheet
EDR 45 IM0011737.PNG Diagonal fan for duct installation, DN 450

Characteristic curve

EDR 45 - Characteristic curve

Dimensioned drawing

EDR 45 - Dimensioned drawing [mm]

Technical data

EDR 45 - Technical data

Article EDR 45
Air flow volume 5.200 m³/h
Air volumenom 3.500 m³/h / in opt. efficiency
Pressure pfs, nom 246 Pa / in opt. efficiency
Rotating speed nnom 1.435 1/min / in opt. efficiency
Rotating speed 1.440 1/min
Impeller type diagonal
Speed controllable
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Nominal output 410 W / in opt. efficiency
Inom 2,3 A / in opt. efficiency
Imax 3,1 A
Degree of protection IP X4
Insulation class F
Mains cable 3 x 1,5 mm²
Installation position vertical / horizontal
Housing material Sheet steel, galvanised
Colour Silver grey
Weight 17,5 kg
Weight including packaging 18,79 kg
Nominal size 450 mm
Width 467 mm
Height 463 mm
Depth 467 mm
Width with packaging 505 mm
Height with packaging 505 mm
Depth with packaging 470 mm
Airstream temperature at IMax 80 °C
Ambient temperature 80 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799806615
Article number 0080.0661
Article EDR 45
Total efficiency η 50 %
Measurement category A
Efficiency category static
Efficiency level N 64,2
VSD necessary No
Year of manufacture see rating plate
Manufacturer’s name / official registration number / manufacturer's place of establishment Maico Elektroapparate-Fabrik GmbH / Freiburg registration court, HRB 601233 / Villingen-Schwenningen
Art. No. 0080.0661
PBEP / Air volumeBEP / Pfs, BEP 0,445 kW / 3.500 m³/h / 246 Pa
nBEP 1.435 1/min
Specific ratio ≈ 1
Information about dismantling and disposal see mounting instructions
Information about installation, operation and repairs see mounting instructions
Objects used to measure efficiency which are not described by the measurement category -
IBEP 2,3 A
Sound power levelLWA5 71 dB(A)

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, Level 2 (dB(A))

67

65

64

68

50

48

37

72

LWA2, Level 3 (dB(A))

64

62

62

67

48

46

36

70

LWA2, Level 4 (dB(A))

65

64

63

67

50

47

37

71

LWA2, Level 5 (dB(A))

66

65

64

68

54

53

41

72

LWA5, Level 2 (dB(A))

68

70

67

67

64

58

51

75

LWA5, Level 3 (dB(A))

64

67

66

67

65

59

52

73

LWA5, Level 4 (dB(A))

63

67

66

67

67

60

54

73

LWA5, Level 5 (dB(A))

75

71

71

71

70

66

59

79

LWA6, Level 2 (dB(A))

75

73

74

72

65

60

52

80

LWA6, Level 3 (dB(A))

74

71

73

73

67

61

53

79

LWA6, Level 4 (dB(A))

75

72

76

74

69

64

56

81

LWA6, Level 5 (dB(A))

77

75

78

76

72

68

60

83

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

Measured at optimised efficiency

Accessories

Product description

Productdescription

EDR 45

short description

Diagonal fan for duct installation, DN 450

Product description

Features

  • For direct installation in ducts.
  • Conveying medium to large air volumes against high resistance.
  • Compact dimensions, low weight and integrated mounting plate facilitate quick installation.
  • The high efficiency reduces operating costs: Purchase price amortises after just one year, depending on operating time.
  • Suction nozzle for low-turbulence air intake.
  • Diagonal impeller with downstream stator.
  • Profiled impeller and stator blades ensure optimum air flow.
  • With diffuser to increase the static pressure.
  • Gap sealing between suction and discharge chamber reduces overflow losses.
  • Meridian flow pattern prevents turbulence.
  • IP X4 degree of protection. Exception EDR 45 to EDR 56 IP 54.
  • Temperature class F.
  • Material: Sheet steel, galvanised.

AC motor

  • Electrical connection via external terminal box.
  • Speed control possible by means of transformers.
  • Thermal overload protection as a standard feature.
  • Depending on the version, the connections of the thermal contacts must be connected to an MVE 10-1 motor protection switch or the control circuit of a contactor.

Table of contents

Wiring diagram

EDR 45 - Wiring diagram

EDR 45 and EDR 50

TK - Thermal contact



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings