Sound-insulated ventilation box

ESR 12 S

No longer available for delivery
Article number: 0080.0227
Manufacturer: MAICO
Sound-insulated ventilation box with swivelling fan, DN 125, single-phase AC

Product data sheet
ESR 12 S IM0009881.PNG Sound-insulated ventilation box with swivelling fan, DN 125, single-phase AC

Characteristic curve

ESR 12 S - Characteristic curve

Dimensioned drawing

ESR 12 S - Dimensioned drawing [mm]

Technical data

ESR 12 S - Technical data

Article ESR 12 S
Air flow volume 330 m³/h
Rotating speed 2.430 1/min
Speed controllable
Type of voltage Alternating current
Rated voltage 230 V
Nominal output 65 W
Inom 0,28 A
Imax 0,3 A
Weight 12
Swivelling fan
Nominal size 125 mm
Airstream temperature at nominal current 75 °C
Ambient temperature 75 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799802273
Article number 0080.0227

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA5, S5 (dB(A))

35

42

40

39

38

32

24

47

LWA6, S5 (dB(A))

44

53

61

61

57

53

43

65

LWA2, S5 (dB(A))

35

40

40

30

25

22

16

44

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

Accessories

ESR 12 S - Accessories

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Automatic backflow preventer AVM 12 0093.0003 on request
  • On the notes
Tubular sound absorber RSR 12 Remaining parts 0092.0312 on request
  • On the notes
Tubular sound absorber RSR 12-1 0092.0593 on request
  • On the notes
Tubular sound absorber RSR 12/50-1 0092.0601 on request
  • On the notes
Electrical air heater ERH 12-1 0082.0101 on request
  • On the notes
Water air heater WRH 12-1 0082.0117 on request
  • On the notes
Air filter TFE 12-4 0149.0075 on request
  • On the notes
Air filter TFE 12-7 0149.0050 on request
  • On the notes
Tubular sound absorber RSR 12/50 No longer available for delivery 0092.0322 on request
  • On the notes
Air filter TFE 12-5 No longer available for delivery 0149.0059 on request
  • On the notes
Heat exchanger WT 300 No longer available for delivery 0152.0020 on request
  • On the notes

General accessories

Product type Name Art. No. Price*(EUR) Action
Shutter AP 120 0059.0950 on request
  • On the notes
External grille SG 120 0059.0951 on request
  • On the notes
Protective grille SGR 12 0150.0124 on request
  • On the notes
5-step switch for TRE...S -2/ TR...S-2 5-step transformers ESS 20 0157.0749 on request
  • On the notes
Speed controller ST 1 No longer available for delivery 0157.0810 on request
  • On the notes
Speed controller STU 1 No longer available for delivery 0157.0814 on request
  • On the notes
Speed controller, distribution board STS 2,5 No longer available for delivery 0157.0255 on request
  • On the notes
TRE 0,4 No longer available for delivery 0016.0110 on request
  • On the notes
5-step transformer, control cabinet TRE 1,6 S No longer available for delivery 0157.0744 on request
  • On the notes

Product description

Productdescription

ESR 12 S

short description

Sound-insulated ventilation box with swivelling fan, DN 125, single-phase AC

Product description

Features

  • Optimised efficiency, low maintenance costs.
  • Removable housing cover with clip-locks.
  • Inlet and outlet side connection couplings for direct installation in ventilation ducts.
  • With sound absorbing rock wool, laminated with silk glass, to meet the increased requirements of especially low noise levels.

Air flow direction

  • The airsteam direction is indicated by an arrow marked on the housing.

Motor

  • External rotor-capacitor motor.
  • Robust motor with ball bearings, maintenance-free.
  • The motor's standard rubber mounting prevents vibrations being transferred to the housing.
  • Temperature classes B or F.
  • IP X4 degree of protection with closed housing cover.

AC motor

  • Thermal overload protection as a standard feature.

Three-phase AC motor

  • Potential-free terminal connections, which must be connected to an MV 25 protective motor switch or the control circuit of a contactor.

Mounting instructions

  • Can be fitted in any position.

Safety instructions

  • The fan may be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN ISO 13857 for fans with free inlet or outlet. To do this, fit a protective grille.

Table of contents

Wiring diagram

ESR 12 S - Wiring diagram



Duct fan with ERH 16-2 R electric air heater

S1 - system on

US16 - all-pole isolating switch (contactor)

ERR... centrifugal duct fan

ERH...R electrical air heater: ERH16-2R

B=Int/ext bridge must be closed

C=Do not change potentiometer setting

D=Setpoint potentiometer for MIN limitation

E=Setpoint potentiometer for MAX limitation

F=Bridge for MAX limitation, bridge must be closed!

G=If bridge is closed, MIN limitation is also active

FR30P - ext. setpoint controller (0-30°C) with room sensor

FL30P - ext. channel sensor for MIN, MAX limitation

LW9 - air flow monitor (in position N)

Installation of LW9 sensor on incoming side of air heater

0-30°C setpoint setting and recording of room temperature with FR30P

0-60°C min/max limitation in supply air channel with FL60P



Duct fan with electric air heater DRH 16-5R and DRH 20-6R

S1 - system on

US16 - all-pole isolating switch (contactor)

ERR... centrifugal duct fan

DRH...R electric air heater: DRH16-2R or DRH20-6R

B=Int/ext bridge must be closed

C=Do not change potentiometer setting

D=Setpoint potentiometer for MIN limitation

E=Setpoint potentiometer for MAX limitation

F=Bridge for MAX limitation, bridge must be closed!

G=If bridge is closed, MIN limitation is also active

FR30P - ext. setpoint controller (0-30°C) with room sensor

FL30P - ext. channel sensor for MIN, MAX limitation

LW9 - air flow monitor (in position N)

Installation of LW9 sensor on incoming side of air heater

0-30°C setpoint setting and recording of room temperature with FR30P

0-60°C min/max limitation in supply air channel with FL60P



Predecessor - successor

ESR 12 S - Successor

Product type Name Art. No. Action
Sound-insulated ventilation box ESR 12-2 S No longer available for delivery 0080.0617
  • On the notes

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings