Axial duct fan

DZR 40/2 B

Article number: 0086.0061
Manufacturer: MAICO
Axial duct fan, DN 400, three-phase AC
Application examples: Machine extraction unit, Showroom, Foreman's office, Workshop, Production site
Product data sheet
DZR 40/2 B IM0009987.PNG Axial duct fan, DN 400, three-phase AC

Characteristic curve

DZR 40/2 B - Characteristic curve

U = 400 V

f = 50 Hz

n = 2850 min-1

Dimensioned drawing

DZR 40/2 B - Dimensioned drawing [mm]

Number of flange holes: 12

Technical data

DZR 40/2 B - Technical data

Article DZR 40/2 B
Air flow volume 9.030 m³/h
Air volumenom 6.515 m³/h / in opt. efficiency
Pressure pfs, nom 355 Pa / in opt. efficiency
Rotating speed nnom 2.930 1/min / in opt. efficiency
Rotating speed 2.953 1/min
Impeller type axial
Speed controllable
Reversing capacity
Type of voltage Three-phase AC
Rated voltage 400 V
Frequency 50 Hz
Nominal output 1.525 W / in opt. efficiency
Inom 2,6 A / in opt. efficiency
Imax 3,5 A
Degree of protection IP 55
Insulation class F
Pole-changeable
Mains cable 7 x 1,5 mm²
Installation position horizontal / vertical
Material Sheet steel, galvanised
Colour Silver
Weight 23,13 kg
Weight including packaging 25,04 kg
Nominal size 400 mm
Width 438 mm
Height 438 mm
Depth 370 mm
Width with packaging 495 mm
Height with packaging 515 mm
Depth with packaging 400 mm
Airstream temperature at nominal current 60 °C
Airstream temperature at IMax 60 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799860617
Article number 0086.0061
Article DZR 40/2 B
Total efficiency η 60,6 %
Measurement category D
Efficiency category total
Efficiency level N 66,2
VSD necessary No
Year of manufacture see rating plate
Manufacturer’s name / official registration number / manufacturer's place of establishment Maico Elektroapparate-Fabrik GmbH / Freiburg registration court, HRB 601233 / Villingen-Schwenningen
Art. No. 0086.0061
PBEP / Air volumeBEP / Pfs, BEP 1,3 kW / 7.990 m³/h
nBEP 2.940 1/min
Specific ratio ≈ 1
Information about dismantling and disposal see mounting instructions
Information about installation, operation and repairs see mounting instructions
Objects used to measure efficiency which are not described by the measurement category -
pf, BEP 355 Pa
Sound power levelLWA5 93 dB(A)

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, S1 (dB(A))

67

LWA2, S2 (dB(A))

79

LWA2, S3 (dB(A))

84

LWA2, S4 (dB(A))

85

LWA2, S5 (dB(A))

48

64

64

79

87

79

74

64

88

LWA5, S1 (dB(A))

80

LWA5, S2 (dB(A))

92

LWA5, S3 (dB(A))

95

LWA5, S4 (dB(A))

95

LWA5, S5 (dB(A))

45

67

72

85

93

92

83

75

96

LWA6, S1 (dB(A))

86

LWA6, S2 (dB(A))

99

LWA6, S3 (dB(A))

102

LWA6, S4 (dB(A))

102

LWA6, S5 (dB(A))

70

74

87

98

99

97

90

82

103

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

Accessories

DZR 40/2 B - Accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
Shutter AS 40 0151.0334 on request
  • On the notes
Shutter, manual RS 40 0151.0342 on request
  • On the notes
Servomotor MS 2 0093.0403 on request
  • On the notes
Control shutter JRE 40 0151.0393 on request
  • On the notes
Servomotor MS 8 0157.0760 on request
  • On the notes
Servomotor MS 8 P 0157.0761 on request
  • On the notes
Internal grille IG 40 0059.0175 on request
  • On the notes
Protective grille, metal SG 40 0150.0118 on request
  • On the notes
Protective grille, synthetic material SGK 40 0059.0165 on request
  • On the notes
Flexible coupling ELA 40 0092.0269 on request
  • On the notes
Flexible cuff EL 40 0092.0091 on request
  • On the notes
Counter flange GF 40 0056.0006 on request
  • On the notes
Counter socket GS 40 0055.0172 on request
  • On the notes
Suction nozzle AD 40 0180.0623 on request
  • On the notes
Mounting foot FU 40 0036.0073 on request
  • On the notes
Vibration damper GP 10 0092.0151 on request
  • On the notes
Main switch, service switch HS 3 0157.0736 on request
  • On the notes
Rotary switch DS 10 0157.0410 on request
  • On the notes
Reversing switch W 1 0157.0101 on request
  • On the notes
Reversing switch WU 1 Discontinued product 0157.0102 on request
  • On the notes
Motor protection switch MV 16-1 0157.1658 on request
  • On the notes
Motor protection switch MV 25-1 0157.1659 on request
  • On the notes
Contactor US 16 T 0157.0769 on request
  • On the notes
Thermostat THR 10-1 0157.0191 on request
  • On the notes
Thermostat TH 10 0157.0764 on request
  • On the notes
Thermostat TH 16 0157.0748 on request
  • On the notes
Air flow monitor LW 9 0157.0779 on request
  • On the notes
Hygrostat HY 230 0157.0126 on request
  • On the notes
Hygrostat HY 230 I 0157.0127 on request
  • On the notes
Air quality controller EAQ 10/1 Discontinued product 0157.0777 on request
  • On the notes
Thermostat THR 10 No longer available for delivery 0157.0774 on request
  • On the notes
Mounting and sealing material BD 40 No longer available for delivery 0092.0136 on request
  • On the notes
Hygrostat HY 10 AP No longer available for delivery 0157.0358 on request
  • On the notes
Hygrostat HY 10 UP No longer available for delivery 0157.0357 on request
  • On the notes
Motor protection switch MV 25 No longer available for delivery 0157.0712 on request
  • On the notes

Product description

Productdescription

DZR 40/2 B

short description

Axial duct fan, DN 400, three-phase AC

Product description

Three-phase AC model

  • Axial duct fan, in three-phase AC version.

Brief description

  • Duct sleeve made of galvanised sheet steel, with flanges on both sides.
  • 8-blade impellers made of glass fibre reinforced polyamide
  • Flange holes in accordance with DIN EN 12220:1998.
  • DZR 56/6 B and DZR 56/4 B: Flange holes in accordance with DIN EN 12220: 1998.
  • To avoid transmission of vibrations to the duct system: Use flexible couplings, feet and vibration dampers.
  • Thermal overload protection as a standard feature.
  • Fans meet the requirements of the European Ecodesign Directive (EC) No.327/2011 Directive 2009/125/EC.
  • Vibration-free running due to dynamically balanced impeller and motor (shaft-rotor), according to quality class 6.3, DIN ISO 1940, part 1.
  • High efficiency on the ventilation side, low operating noise.
  • Increased durability due to high-quality materials such as quiet ball bearings.
  • Fans are maintenance-free.
  • Can be fitted in any position.

Air flow direction

  • The air flow direction is marked.
  • Standard exhaust air mode, air flow direction with air drawn across motor.

Three-phase AC motor

  • DZR type series.
  • Asynchronous motor.
  • Not suitable for ventilating steam-saturated air.
  • Rated voltage 400 V, 50 Hz.
  • High degree of protection IP 55. Exception DZR... D IP 54.
  • Speed-controllable. Exception for type DZR 40/2 B.
  • Units can be switched in steps with an optional 5-step transformer.
  • Reversible.
  • Reversing mode: The volumetric flow is reduced by approx. 35 % with abnormal air flow direction.
  • Thermal overload protection as a standard feature. Exception for type DZR 25/4 D and pole-changeable axial duct fans, available on request.
  • Potential-free terminal connections, which must be connected, e.g., to an MV 25-1 motor protection switch or the control circuit of a contactor.
  • Pole-changeable fans: Ensure overload protection is guaranteed by a motor protection switch provided by the customer.

Electrical connection

  • Terminal box with cable sleeves fitted on the outside.

Safety information

  • The fan may be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN ISO 13857, e.g., with Maico SG protective grille.

Special versions

  • The following special versions are available on request, at an extra cost:
    • Special voltages and frequencies.
    • PTC thermistor, potential-free terminal connection.
    • Condensation drainage holes.
    • Fans with enhanced anti-corrosion protection.
    • Impellers made of aluminium.
  • Information on operation at temperatures occasionally below -20°C available upon request.
  • If operating with frequency converters, the factory must be consulted.
  • Feasibility must be checked in each case.

Table of contents

Wiring diagram

DZR 40/2 B - Wiring diagram

MV 25-1 motor protection switch


With MV 25-1 motor protection switch and TR... 5-step transformer


Pole-changeable, 2 speeds, with Dahlander circuit, with motor protection switch


Predecessor - successor

DZR 40/2 B - Predecessor

Product type Name Art. No. Action
Axial duct fan DZL 40/2 B No longer available for delivery 0086.0084
  • On the notes

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings