Fan insert

ER EC

Article number: 0084.0360
Manufacturer: MAICO
ER EC fan insert for ER GH flush-mounted housing and ER GH AP / ER GH APB surface-mounted housing, air volume... more information
Application examples: Bathroom, Kitchen, Multiple family unit, Day room, Dining room
Product data sheet
ER EC IM0017284.PNG ER EC fan insert for ER GH flush-mounted housing and ER GH AP / ER GH APB surface-mounted housing, air volume 30 m³/h / 60 m³/h
ER EC IM0007254.PNG ER EC fan insert for ER GH flush-mounted housing and ER GH AP / ER GH APB surface-mounted housing, air volume 30 m³/h / 60 m³/h

Characteristic curve

ER EC - Characteristic curve ER EC with ER GH exhaust opening at rear and ER GH AP/APB

I – level 1

II – level 2

  1. Factory settings for base and nominal load level in conjunction with ER-A cover
  2. Alternative settings for base and nominal load levels in conjunction with ER-AK/..-AH/..-AB covers

ER EC - Characteristic curve ER EC and ER EC RF17 with ER GH exhaust opening at side

I – level 1

II – level 2

  1. Factory settings for base and nominal load level in conjunction with ER-A cover
  2. Alternative settings for base and nominal load levels in conjunction with ER-AK/..-AH/..-AB covers

Dimensioned drawing

Technical data

ER EC - Technical data

Article ER EC
Air flow volume 20 m³/h / 30 m³/h / 40 m³/h / 60 m³/h / 100 m³/h / Levels can be set in a variable manner depending on cover variant. ER-A: Level 1 = 30 m³/h, level 2 = 60 m³/h. ER-AK/ER-AB: Level 1 and level 2 = 20/30/40/60/100 m³/h can be set. ER-AH: Level 1 = 20/30/40 m³/h, level 2 = 60/100 m³/h can be set.
Rotating speed 500 1/min / 800 1/min / 1.050 1/min / 1.250 1/min / 1.800 1/min / combined with ER GH, ER GH AP/APB
Air direction Air extraction
Speed controllable
Reversing capacity
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Power consumption 2 W / 2,5 W / 3 W / 5 W / 17 W / Combined with ER GH; 2.4 W / 2.9 W / 3.6 W / 6.2 W / 17 W combined with ER GH AP/APB
Degree of protection IP X5
Mains cable 3/5 x 1.5 mm²
Installation site Wall / Ceiling
Type of installation Recessed-mounted
System type Decentralised
Housing material Polypropylene (PP)
Colour Black
Weight 0,64 kg
Weight including packaging 0,91 kg
Filter class ISO Coarse 30 % (G2)
Air outlet direction at side / at rear
Width 213 mm
Height 233 mm
Depth 115 mm
Width with packaging 280 mm
Height with packaging 280 mm
Depth with packaging 152 mm
Airstream temperature at IMax 40 °C
Sound pressure level 15 dB(A) / 16 dB(A) / 23 dB(A) / 35 dB(A) / 48 dB(A) / combined with ER GH; 27 dB(A) / 31 dB(A) / 35 dB(A) / 41 dB(A) / 51 dB(A) combined with ER GH AP/APB/ Specification according to DIN 18017-3 with an equivalent absorption area of AL = 10 m²
Approval number Z-51.1-478
Packing unit 1 piece
Range B
GTIN (EAN) 4012799843603
Article number 0084.0360

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA7, S1 (dB(A))

19

LWA7, S2 (dB(A))

20

LWA, S3 (dB(A))

27

LWA, S4 (dB(A))

39

LWA, S5 (dB(A))

52

LWA7= housing and free inlet sound power level in dB.

in combination with ER GH; 31 dB(A) / 35 dB(A) / 39 dB(A) / 45 dB(A) / 55 dB(A) in combination with ER GH AP/APB

Product description

Productdescription

ER EC

short description

ER EC fan insert for ER GH flush-mounted housing and ER GH AP / ER GH APB surface-mounted housing, air volume 30 m³/h / 60 m³/h

Product description

Special features

  • Robust, energy-saving and sound-optimised EC motor with constant volumetric flow.
  • Low power consumption.
  • Can be used for flush mounting or surface mounting.
  • Ventilation solution in accordance with DIN 18017-3 (single duct air extraction).
  • National technical approval, approval no.: Z-51.1-38;
  • Certificates of approval on request or on our website – www.maico-ventilatoren.com.
  • Degree of protection IP X5, installation in protection zone 1 possible.
  • The ER EC fan insert can be combined with the four existing covers ER-A, ER-AK, ER-AH, ER-AB and adapted to the individual situation.
  • Can be used in conjunction with the ER-RPK replacement kit in existing ER housings (ER-UP/G, ER-UPB, ER-UPD).

Features

  • 2-level fan for installing in ER GH flush-mounted housing and ER GH AP/ER GH APB surface-mounted housing.
  • Air volume 30 m³/h / 60 m³/h in conjunction with the ER-A standard cover.
  • When using the covers (ER-AK, ER-AH, ER-AB), 20 / 30 / 40 / 60 / 100 m³/h also possible.
  • Start delay 60 s.
  • Overrun time 15 min.
  • For single or second room air extraction using a single fan. Accessories for ER-ZR second room air extraction.
  • Air outlet adapter can be installed, without tools, for side and rear air outlet; included as a standard feature.
  • Simple and quick installation of the fan in the housing via the snap-on attachment and the electrical plug connector.
  • All MAICO ER units have an IP X5 degree of protection and can be installed in area 1 in accordance with DIN VDE 0100-701, even with water jets. For details see planning instructions.
  • Protection class II.
  • The steep characteristic curve shows the high pressure capacity of the ER EC fan.
  • Robust energy-saving EC motor.
  • Motor with thermal overload protection.
  • Maintenance-free, with enclosed ball bearings on both sides.
  • Shaft level difference according to DIN 52210-6, tested by the Frauenhofer Institute.

Table of contents

Wiring diagram

ER EC - Wiring diagram

Connection variant 1, full load for ER-A, ER-AK, ER-AH, ER-AB

opt - optional

MS - motor control

Full load can be switched, no base load operation

Connection is made in the housing



Connection variant 2, base load/full load for ER-A, ER-AK, ER-AH, ER-AB

opt - optional

MS - motor control

Full load can be switched with permanent base load

Connection is made in the housing



Connection variant 3, base load/full load for ER-A, ER-AK, ER-AH, ER-AB

opt - optional

MS - motor control

Base and full load can be switched

Connection is made in the housing



Connection variant for interval, humidity, movement for ER-AK, ER-AH, ER-AB

MS - motor control

Connection is made in the housing



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings