WRG300W IM0022788.PNG Centralised and decentralised ventilation units with heat recovery, central exhaust air units, ventilation duct systems

Characteristic curve

WRG300W - Characteristic curve

Dimensioned drawing

WRG300W - Dimensioned drawing [mm]

Technical data

WRG300W - Technical data

Article WRG300W
Rotating speed 2.070 1/min
Type of voltage Alternating current
Rated voltage 230 V
Frequency 60 Hz
Power consumption 30 W / 50 W / 95 W
Imax 6,9 A
Degree of protection IP 00
Electrical plug-type connection Earthing contact
Installation site Cellar / Storage tank / Jamb wall / Utility room / Heating room
Housing material Sheet steel, galvanised
Colour Pure white, similar to RAL 9010
Weight 80 kg
Filter class G3 / F7
Connection diameter 160 mm
Degree of heat provision 92 %
Heat exchanger construction type Condensation rotor
Packing unit 1 piece
Article number 0082.0038

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, high (dB(A))

29

34

29

33

24

22

20

16

38

LWA5, high (dB(A))

28

37

39

40

40

40

34

26

48

LWA6, high (dB(A))

18

27

26

31

39

26

17

8

41

LWA2= housing sound power level in dB.

LWA5= free inlet sound power level in dB.

LWA6= free outlet sound power level in dB.

Accessories

WRG300W - Accessories

Specific accessories

Product type Name Art. No. Price*(EUR) Action
Electrical air heater ERH 16-2 0082.0102 on request
  • On the notes
Water air heater WRH 16-2 0082.0118 on request
  • On the notes
Air filter, replacement ZF 300 0093.0696 on request
  • On the notes
Tubular sound absorber RSR 16 No longer available for delivery 0092.0314 on request
  • On the notes
Wall bracket WSK 250 No longer available for delivery 0018.0223 on request
  • On the notes
Air filter TFE 16 No longer available for delivery 0149.0042 on request
  • On the notes
Hygrostat HY 5 No longer available for delivery 0157.0123 on request
  • On the notes
Hygrostat HY 5 I No longer available for delivery 0157.0125 on request
  • On the notes

Product description

Productdescription

WRG300W

short description

Centralised and decentralised ventilation units with heat recovery, central exhaust air units, ventilation duct systems

Product description

Features

  • 92 % degree of heat provision.
  • Automatic volumetric flow regulation for constant air volume.
  • Special energy savings due to the DC motor.
  • Galvanised plate housing, RAL 9010 plastic powder coated surface, sandwich construction, with integrated heat insulation.
  • Integrated filter system with coarse filter (G3) and dust filter (F7) fitted in the outside air, coarse filter (G3) fitted in the exhaust air. The fabric replacement filter can be exchanged without tools.
  • Electronic filter monitoring with filter change warning displayed on the control unit.
  • 4 DN 160 duct connections with rubber lip seals on top of the unit. For directly connecting up tubular sound absorbers.
  • Controlled by the control unit in the living room.
  • Control unit for switching ventilation levels, timer, filter pollution.

Heat exchanger

  • Counterflow heat exchanger made of synthetic material (PS).
  • The heat exchanger can be easily removed and cleaned with water.

Frost protection

  • Heat recovery systems combined with earth heat exchangers or an electric frost protection feature to also ensure perfect operations at low temperatures. In the winter, the earth heat exchanger guarantees extra heating power and in the summer, extra cooling power.

Heat recovery fan

  • 2 centrifugal DC fans with integrated converter, one fan each for supply air and exhaust air.
  • 3 ventilation steps: 1 = economy setting, 2 = normal, 3 = high.

Mounting instructions

  • Mounting on the wall or a pedestal is required to endure access to the condensation connection.
  • For installation or wall fitting using a bracket: In cellars, attics and engineering rooms.
  • The front plate can be unscrewed.

Condensation drain

  • The condensation is drained from the bottom of the unit using a hose (DN 1/2") connected to a siphon.

Table of contents

Wiring diagram

WRG300W - Wiring diagram

WRG 300 W

S1 On / Off

S2 WRG in level 2

S3 WRG in level 3

V1 distributor (to be provided by the customer)

M1 exhaust air fan

M2 supply air fan

F1 frost protection



Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings