Operating the unit
ER-UP/Centro units are usually switched on and off manually (using a switch), depending on unit model and connection variant.
Barrier-free units work as per the automatic function. Alternatively, these units can be operated using an optional switch.
Please read the relevant sections in these instructions (ER-UP controls (circuit board types)) or contact your installer or planner for details of the special functions and operating characteristics.
Control model standard, D, VZ, VZC, G, GVZ, I and RC
The unit is switched on and off with a switch that is to be provided by the customer.
Control model F
Barrier-free unit. The fan switches on once the room lighting is activated. The fan can also be operated manually using an optional switch (Wiring diagrams).
Control model H
Barrier-free unit. The unit switches on when the humidity reference value Rf is exceeded. No switch needed. The unit can also be operated manually using an optional switch (Wiring diagrams).
Control model RC
Radio-controlled fan system with up to 3 ER 100 RC fans. These are switched on and off via a radio switch, room air control RLS RC or radio window contacts.