Characteristic curve
Dimensioned drawing
Technical data
Accessories / Accessories of
Product type | Name | Art. No. | Price*(EUR) | Action |
---|---|---|---|---|
Power module | PP 45 LT | 0157.0361 | on request | |
EnOcean extension module | PP 45 EO | 0157.0362 | on request | |
Humidity sensor | PP 45 HYI | 0157.0364 | on request | |
Humidity sensor | PP 45 HY | 0157.0365 | on request | |
CO2 sensor | PP 45 CO2 | 0157.0366 | on request | |
VOC sensor | PP 45 VOC | 0157.0367 | on request |
Product type | Name | Art. No. | Price*(EUR) | Action |
---|---|---|---|---|
Final assembly kit | PPB 30 K | 0095.0246 | on request | |
Final assembly kit | PPB 30 O | 0095.0245 | on request | |
Final assembly kit | PPB 30 RC | 0095.0244 | on request | |
Final assembly kit | PP 45 K | 0095.0241 | on request | |
Final assembly kit | PP 45 O | 0095.0240 | on request | |
Final assembly kit | PP 45 RC | 0095.0242 | on request |
Product description
Productdescription
Wiring diagram
RLS 45 K - PushPull 45 comfort room air control
PP 45 K - PushPull 45 comfort fan unit
Fan 1.1 - fan unit 1, unit pair 1
Fan 2.1 - fan unit 2, unit pair 1
Fan 1.2 - fan unit 1, unit pair 2
Fan 2.2 - fan unit 2, unit pair 2
Fan 1.3 - fan unit 1, unit pair 3
Fan 2.3 - fan unit 2, unit pair 3
S1 - Button/switch for additional function (sleep, intensive, disbalance, safety function)
UP-L -Recessed-mounted distributor connection for fan units, connection of all fan units in star shape to distributor
W-F1 - Fan 1 control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. length to distributor 4m.
W-F2 - Fan 2 control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. length to distributor 4m.
W1.X - Fan unit control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25m.
W2.X - Fan unit control cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25m.
W3 - Bus (RS-485) connection cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. cable length to the sensors, RLS, LT and EnOcean module approx. 100m. Alternatively, this connection can also be used as a ModBus RTU interface.
RLS 45 K - PushPull 45 Comfort room air control
PP 45 K - PushPull 45 Comfort fan unit
PPB 30 K - PushPull Balanced 30 Comfort fan unit
Fan 1.1 - fan unit 1, unit pair 1
Fan 2.1 - fan unit 2, unit pair 1
Fan 1.2 - fan unit 1, unit pair 2
Fan 2.2 - fan unit 2, unit pair 2
S1 - Button/switch for additional function (sleep, intensive, disbalance, safety function)
UP-L - Recessed-mounted distributor connection, connection of all fan units in star shape to distributor
W-F1 - Fan 1 control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. length to distributor 4m.
W-F2 - Fan 2 control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. length to distributor 4m.
W-B1 - Bus PPB control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. length to distributor 4m.
W1.X - Fan unit control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25m.
W2.X - Fan unit control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25m.
W-PPB - BBP 30 (bus) control cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. cable length from UP-L distributor to PP 45 ventilation unit = 25m.
W3 - Connecting cable switch/pushbutton for activation of special functions (exhaust air mode, intensive ventilation), recommended control cable LiYY 2*0.5 mm². Max. cable length 25 metres.
RLS 45 K - PP 45 Comfort room air control
PP 45 LT - PP 45 power unit
PP 45 EO - PP 45 EnOcean radio module
PP 45 HY - PP 45 humidity sensor for recessed mounting
PP 45 CO2 - PP 45 CO2 sensor for recessed mounting
PP 45 VOC - PP 45 VOC sensor for recessed mounting
Fan 1.1-1.3 - Fan unit 1 and 3 on RLS master
Fan 2.1-2.3 - Fan unit 2 and 4 on RLS master
W-PPB - Fan unit 5 (BBP 30 K) on RLS master connecting cable for bus (RS-485), recommended control cable J-Y(ST)Y 2x2x0.8mm². Max. cable length to the PPB 30 K, 25 metres from the star point
Fan 3 + 4 G1-3 - Fan unit 6,7,8 on RLS slave 1
Fan 5.1-5.3 - Fan unit 9,11,13 on RLS slave 2
Fan 6.1-6.3 - Fan unit 10,12,14 on RLS slave 2
S1 - Button/switch for additional function (sleep, intensive, disbalance, safety function)
UP-B - Recessed-mounted distributor bus, connection of RLS, LT, EO and sensors using RS-485 bus interface
W1.X - Bus (RS-485) connection cable, recommended control cable J-Y(ST)Y 2x2x0.8mm. Max. cable length to the sensors, RLS, LTs and EnOcean module approx. 100 m. Alternatively, this connection can also be used as a ModBus RTU interface.
RLS 45 K - 45 comfort room air control / ModBus interface also available for object variant.
X1.1 - terminal mains connection
X1.2 - connection terminal bus/fan
W1 - GLT (ModBus) connection cable, recommended control cable J-Y (ST) Y 2x2x0.8mm. Max. cable length to gateway approx. 100m. Set parameters and undertake addressing by means of service mode or IBS* (commissioning software)
*IBS only in conjunction with the RLS 45 K
Interface info:
ModBus mode: RTU
Baud rate: 9600/19200
Data bits 8
Parity: Even
Stop bits 1
Address: 10 (basic setting)
Downloads / Videos
Predecessor - successor
Product type | Name | Art. No. | Action |
---|---|---|---|
Room air control | RLS PP-K | 0157.0199 |
On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.
Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.
Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.
These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.