Centrifugal roof fan

DRD 18/2 B

No longer available for delivery
Article number: 0087.0099
Manufacturer: MAICO
Centrifugal roof fan, vertical air outlet, DN 180, three-phase AC
Application examples: Production facility, Workplace, Commercial premises, Industrial building, Restaurant
Product data sheet
DRD 18/2 B IM0009963.PNG Centrifugal roof fan, vertical air outlet, DN 180, three-phase AC

Characteristic curve

DRD 18/2 B - Characteristic curve

Dimensioned drawing

DRD 18/2 B - Dimensioned drawing [mm]

  1. Clear width
  2. External duct diameter
  3. Number of holes: 3

Technical data

DRD 18/2 B - Technical data

Article DRD 18/2 B
Air flow volume 1.600 m³/h
Rotating speed 2.850 1/min
Speed controllable
Reversing capacity
Rated voltage 400 V
Nominal output 380 W
Inom 0,72 A
Imax 0,85 A
Degree of protection IP 55
Installation site Roof
Installation position vertical
Material Sheet steel, galvanised
Weight 21,9
Weight including packaging 24,2 kg
Shutter integrated
Type of shutter Airstream-operated opening/closing
Nominal size 180 mm
Width with packaging 535 mm
Height with packaging 435 mm
Depth with packaging 535 mm
Airstream temperature at nominal current -20 °C up to 60 °C
Packing unit 1 piece
Range C
GTIN (EAN) 4012799870999
Article number 0087.0099

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA5, S1 (dB(A))

29

45

50

51

53

60

58

38

63

LWA5, S2 (dB(A))

36

48

61

62

63

61

67

50

70

LWA5, S3 (dB(A))

43

51

67

66

68

66

69

62

74

LWA5, S4 (dB(A))

46

54

70

71

73

71

68

70

78

LWA5, S5 (dB(A))

47

55

70

78

76

73

70

73

82

LWA8, S1 (dB(A))

30

46

49

55

57

60

55

38

63

LWA8, S2 (dB(A))

37

51

59

64

66

67

65

50

72

LWA8, S3 (dB(A))

49

56

65

70

72

72

69

63

77

LWA8, S4 (dB(A))

47

60

70

75

77

76

70

70

82

LWA8, S5 (dB(A))

50

60

71

78

79

79

72

72

84

LWA5= free inlet sound power level in dB.

LWA8= housing and free outlet sound power level in dB.

Accessories

DRD 18/2 B - Accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
Flexible coupling ELA 18 0092.0283 on request
  • On the notes
Socket sound absorber SD 18 0092.0337 on request
  • On the notes
Rotary switch DS 10 0157.0410 on request
  • On the notes
Contactor US 16 T 0157.0769 on request
  • On the notes
5-step switch for TRE...S -2/ TR...S-2 5-step transformers DSS 20 0157.0750 on request
  • On the notes
Thermostat THR 10-1 0157.0191 on request
  • On the notes
Thermostat TH 10 0157.0764 on request
  • On the notes
Thermostat TH 16 0157.0748 on request
  • On the notes
Air flow monitor LW 9 0157.0779 on request
  • On the notes
Air quality controller EAQ 10/1 Discontinued product 0157.0777 on request
  • On the notes
Roof socket for flat roofs SO 18 0093.0887 on request
  • On the notes
Roof socket for flat roofs, tiltable SOK 18 0093.1030 on request
  • On the notes
Roof socket for pitched roofs SDS 18 0093.1028 on request
  • On the notes
Roof socket for corrugated and trapezoidal roofs SOWT 18 0093.1031 on request
  • On the notes
Intermediate socket SZ 18 0092.0286 on request
  • On the notes
Thermostat THR 10 No longer available for delivery 0157.0774 on request
  • On the notes
Exhaust air silencer SDA 18 No longer available for delivery 0092.0385 on request
  • On the notes
5-step transformer TR 2,5-1 No longer available for delivery 0157.0372 on request
  • On the notes
5-step transformer TRV 1,0-1 No longer available for delivery 0157.0532 on request
  • On the notes
5-step transformer, control cabinet TR 2,5 S No longer available for delivery 0157.0742 on request
  • On the notes
Temperature control system ATS No longer available for delivery 0157.0759 on request
  • On the notes
Temperature control system, power module ATL 2,5 No longer available for delivery 0157.0757 on request
  • On the notes
Hygrostat HY 5 No longer available for delivery 0157.0123 on request
  • On the notes
Hygrostat HY 5 I No longer available for delivery 0157.0125 on request
  • On the notes
Hygrostat HY 10 AP No longer available for delivery 0157.0358 on request
  • On the notes
Hygrostat HY 10 UP No longer available for delivery 0157.0357 on request
  • On the notes
Motor protection switch MV 25 No longer available for delivery 0157.0712 on request
  • On the notes

Product description

Productdescription

DRD 18/2 B

short description

Centrifugal roof fan, vertical air outlet, DN 180, three-phase AC

Product description

Features

  • Attractive housing made of galvanised sheet-steel.
  • Cover easily detachable for cleaning purposes.
  • Galvanized protective grille on the discharge side, protection against accidental contact in accordance with DIN EN ISO 13857.
  • Sturdy eyebolts enable transport by crane.
  • Impeller with blades curved to the rear, dynamically balanced at two levels, in accordance with performance level 6.3, DIN ISO 1940.
  • Impeller made of glass-fibre filled polypropylene.

Three-phase AC motor

  • DRD model series.
  • Rated voltage 400 V, 50 Hz.
  • Thermal overload protection as standard feature, except: available on request for pole-changeable fans.
  • Potential-free terminal connections, which must be connected to an MV 25 protective motor switch or the control circuit of a contactor.
  • Pole-changeable fans: Ensure overload protection is guaranteed by a protective motor switch provided by the customer.
  • DRD 25/64 B: Star / delta switch must be provided by the customer.

Electrical connection

  • To terminal block in the service switch.

Safety instructions

  • The fan can be operated only if the protection against accidental contact with the impeller is guaranteed to be in accordance with DIN EN 13857 for fans with a free inlet.

Special versions

  • The following special versions are available at extra cost on request:
    • Special voltages and frequencies.
    • Single-phase motors with thermal contacts or PTC thermistor, with potential-free terminal connections.
    • Fans with enhanced anti-corrosion protection.
  • Information on operation at temperatures occasionally below -20°C available upon request.
  • If operating with frequency converters, the factory must be consulted.
  • Feasibility must be checked in each case.

Table of contents

Wiring diagram

DRD 18/2 B - Wiring diagram









Predecessor - successor

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings